Gasses-66

Industrial Degreaser Solvent Natural No VOC's

Formulated for use in applications where rinsibility is critical, Natural Solv-S is tested and proven to be a safe, effective and powerful soy cleaner for use in many industries including. We are one of popular to manufacture and supplier of Industrial degreaser solvent based.

Alias: 

Natural Degreaser Biodegradable No VOC Natural

Application: 

One of the safest, most economical Soy Degreaser / Cleaners biodegradeable degreaser, mastic cleaner.

  • Non-toxic Solvent

  • Excellent Rinsibility

  • Non Abrasive

  • Concentrated, Economical

  • VOC Free Solvent

  • Biodegradable cleaner

  • High Flash Point

  • No Caustic Fumes

  • Stronger Cleaning Power

  • VOC Free Degreaser

Packing Size: 
25.00 Ltr.
Using Procedure: 

How to clean oily greasy mess like grease, paint, oil,lubricants and other water insoluble materials, your answer must be use suitable Degreaser.

Note: 

Industrial Degreaser Solvent based used in many industries including all such field...

  • Industrial/Manufacturing
  • Electronics
  • Paint Gun Clean-up
  • Asphalt Maintenance
  • Graphic & Jet Ink Clean-up
  • Graffiti Removal
  • Grease & Oil Clean-up
  • Mastic Remover
  • Adhesive Removal
  • Heavy Lube Clean-up
  • Tar & Asphalt Removal
  • Decal Removal
  • Hydrocarbon Cleaning
  • Rubber Compound Cleaning
  • Paint Clean-up
  • Parts Cleaning Solvent
Short Description: 
Formulated for use in applications where rinsibility is critical, Natural Solv-S is tested and proven to be a safe, effective and powerful soy cleaner for use in many industries

Industrial Degreaser Solvent emulsify and dissolves most of oily and soily materials quickly and effectively.

How to clean oily greasy messes like grease, paint, oil, lubricants, and other water-insoluble materials, your answer must be to use a suitable Degreaser.

Solvent based Industrial Degreaser manufacturer and supplier in Mumbai MIDC Maharastra, Kandla Gandhidham, Surat Gujrat Chennai - Ennore, Visakhapatnam, Kolkata Haldai, Fujairah, Dubai, Sharjah, Abudhabi, Ruwi Barka Muscat Oman

Solvent Based Degreaser

One Shot Universal Liquitreat 100

Boiler Water treatment specialized is a well - balanced blend for boiler water treatment products, Resulting in a scale and corrosion control by one shot operation. A one-step treatment to control the formation of rust and scale in low pressure and auxillary boilers with working pressure up to 20 bars.

Alias: 

RXSOL BWT LIQUID PLUS, Care Treat 3 Boiler 2, Drew Ameroid, Arboiler WT, BWT 104P Nor chem, B.W.T. NEW FORMULA EQUAL TO DREW - AGK 100, DM-511, EAZY BWT-1, MAXTREAT-3222, ONE SHOT BWT 25 Ltr

Active Matter: 
54-60
Application: 

The dosage rate is dependent on bioler operating condition, feed 2-3 ltrs of RXSOL-50-5001-025 solution for per thousand ltr of bioler water then control the system by periodic Alkalinity test procedure. If p-Alkalinity is below 200 ppm increase the ratio of RXSOL BWT 5001 solution. If p-Alkalinity is above 400 ppm reduce the concentration of RXSOL-50-5001-025 solution by dilution with water. RXSOL-50-5001-025 is strongly alkaline.RXSOL-50-5001-025  is best applied heat or diluted with any convenient strength on a continuous basis using a suitable chemicals pump. The product should be applied to the boiler feed tank or feed line to ensure adequate mixing.

Packing Size: 
25.00 Ltr.
Using Procedure: 

Control is by simple  boiler water tests or RX CLEANSERS  can provide a suitable test  kits for this purpose.

Used in low pressure and auxillary boilers

:::::::::::::::::::::Alkalinity  TEST FOR BOILER & COOLING WATER ::::::::::::::::::::::::

REAGENT & APPARATUS :
Reagent:  RXSOL TK 7 , TK 8 , TK 9 , . Apparatus : TEST TUBE , Titrator or DROPPER

PROCEDURE for p-ALKALINITY  test ( STEP WISE ):

  1. Measure 10 ml of SAMPLE WATER in graduated TEST TUBE / CYLINDER
  2. Add 1-2 drops of  RXSOL TK7 and mix with the stirring rod , If  sample turns red / PINK ( which indicates presence of p-Alkalinity ) then follows 3rd step otherwise if sample remains colourless ( Record p-Alkalinity = 0 ) .
  3. Add RXSOL TK9  drop by drop ( by counting ) , mixing with the stirring rod until colour just disappears. Each drop is equivalent to 25 ppm of p-Alkalinity , expressed as CaCO3

RESULT  : Each DROPS is equivalent to  25 PPM of Alkalinity .

NOTE :    p-Alkalinity VALUE  =  25 X ( Total Number of DROPS of TK9 , during 3rdstep  )

        

PROCEDURE for p-ALKALINITY  & TOTAL ALKALINITY ( STEP WISE ):

  1. Measure 10 ml of SAMPLE WATER in graduated TEST TUBE / CYLINDER
  2. Add 1-2 drops of  RXSOL TK7 and mix with the stirring rod , If  sample turns red / PINK ( which indicates presence of p-Alkalinity ) then follows 3rd step otherwise if sample remains colourless ( Record p-Alkalinity = 0 ) then proceed to STEP- 4.
  3. Add RXSOL TK9  drop by drop ( by counting ) , mixing with the stirring rod until colour just disappears. Each drop is equivalent to 15 ppm of p-Alkalinity , expressed as CaCO3
  4. Add 2-3 drops of RXSOL TK8 and mix with stirring rod , the sample will turn to BLUISH-GREEN .
  5. AddRXSOL TK9 carefully by counting drop by drop and mixing throughly until a light reddish  pink  colour develop.

RESULT  : Each DROPS is equivalent to 25 PPM of Alkalinity .

NOTE :    p-Alkalinity ppm CaCO3VALUE ( A )  =  25 X ( Total Number of DROPS of TK9 , during 3rdstep  )

Total Alkalinity ppm CaCO3VALUE  =  A +  { 25 X ( Total Number of DROPS of TK9 , during 5th step  )}

 

 

 

NUMBER OF DROPS OF TK9                                                                                     p-Alkalinity as CaCO3                                

                        1 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>25
                        2 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>50

                        3 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>  75
                        4 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>  100

                        5 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> > 125
                       10 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> >  250

                       20 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> >  500
                       30>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> >750

                       40 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>  1000
 

Optimum Result    :   p-Alkalinity  level  is between 100 to  150 PPM is suggested.

 if  p-Alkalinity level is more then 150 ppm then level should be reduced by increased BLOW DOWN process with immediate effect.   

For Below  50 ppm  , Dose ½ Ltrs of RXSOL-50-5001-025 for 1000 Ltrs of  BOILER WATER , to maintain p-Alkalinity level 100 ppm.

Refill pack : REPLACEMENTS  

TK7   : ECONOMIC PACK ( 100 / 200 / 500 ml ) available

TK8   : ECONOMIC PACK ( 100 / 200 / 500 ml ) available

TK9   : ECONOMIC PACK ( 100 / 200 / 500 ml ) available

Short Description: 
A one-step and one SHOT treatment to control the formation of rust and scale in boilers. Contains alkaline compounds, scale and corrosion inhibitors, oxygen scavengers and sludge conditioners

Chemical feed should be continuous. Chemical pumping rates can create problems especially for neat feed set ups. Using on/off feed systems such as a recycle timer can create problems. Chemical feed pumps should be sized or product strengths should be adjusted to allow continuous feed.

Steam and carbon dioxide leave continuously, so setting up a neutralizing amine pump to feed intermittently can lead to wide variations in condensate pH control. If sampling is done from a condensate receiver, the tank volume may buffer the variations and the changes may not be noticed, but corrosion could be occurring to areas of the piping that see the rapidly changing pH.

If polymeric dispersants, phosphonates, phosphate, or chelants are fed intermittently into the feedwater using a recycle timer, and the amines are not fed continuously, a cycle of iron slugs returning in the condensate can be followed by slugs of high dispersancy cleaning of the iron from the deaerator and dragging it into the boiler.

Load changes can affect chemical concentrations when the chemical feed is base fed. Example: Steam production of one million lbs./day; 4% blowdown; 20% active boiler polymer product fed at 5 pounds per day. The calculated daily average polymer concentration would be 24 ppm. Assume peak plant production load is 60,000 lbs./hr., but during the overnight hours the load is only 5,000 lbs./hr. If the dispersant is being fed continuously over the 24 hours, during the 8- hour low load period, the boiler polymer concentration would have increased to over 200 ppm. Upon high fire when production resumes, carryover is very possible because of over concentrating the polymeric dispersant.

Chemical feed needs to be paced to steam production, especially where significant load changes occur.

Carbon dioxide can concentrate in steam and condensate making neutralizing amine treatment impractical. Carbon dioxide levels can be relatively low in steam exiting a boiler at only a few ppm, but if there are areas where it becomes “trapped” and can accumulate, concentrations can reach extremely high levels into the hundreds or even thousands of ppm.

CO2 is a non-condensable gas. It has a distribution ratio in the steam piping and condenses at points throughout the system. At the boiling point, the solubility of the gas in water is extremely low. The solubility of the CO2 is actually lower in the condensate than it is in the steam. For the CO2 to escape from the steam into the water it will accumulate in the steam space just above the water level until the partial pressure becomes high enough for the CO2 in the incoming steam to be able to exit into the condensate. This creates a steady state condition of CO2 coming in and exiting, but an area of severe localized corrosion occurs where the carbon dioxide concentration is high.

The highest CO2 concentration normally occurs just above the condensate water level. If there is an area where condensation is occurring and running down pipes or the sides of vessels, the CO2 concentration will be very high and the pH will be about 5.3 – 5.5 in that location creating high corrosion rates.

The solubility of CO2 increases dramatically as the condensate temperature falls below 212 °F. When there is an accumulation of CO2 in an area and the condensate temperature is relatively low, the amount of carbon dioxide going into solution will be extremely high. Where low-pressure steam is used that contains CO2 and the heat exchange process has relatively close temperature differentials between the steam and the condensate, there is potential for high uptake of the CO2 into the condensate and localized low pH.

Neutralizing amines are selected in an effort to condense in the right concentrations to carbon dioxide condensation levels throughout the steam system. Neutralizing amines cannot control corrosion where this localized accumulation of carbon dioxide occurs since the high CO2 overwhelms the demand for the amine. Even point source addition of amine may not be able to satisfy the demand.

Where the concentrating effect of CO2 occurs, methods of reducing the problem include eliminating or minimizing CO2 in the steam, venting off the CO2 in the localized area, eliminating condensate in the area, applying a filming amine or metal passivator, or using higher temperature steam and increasing condensate temperature to reduce the CO2 content in the condensate.

#BoilerWaterTreatmentCHEMICAL_supplierDUBAI
#BoilerWaterTreatmentCHEMICAL_supplierMUSCAT
#BoilerWaterTreatmentCHEMICAL_supplierMUMBAI
#BoilerWaterTreatmentCHEMICAL_supplierNAIROBI

A one-step and one SHOT treatment to control the formation of rust and scale in boilers. Contains alkaline compounds, scale and corrosion inhibitors, oxygen scavengers and sludge conditioners. which resulting in a scale and corrosion control by one shot operation.

Boiler water treatment speacialized chemical products One Shot Universal Liquitreat  Exporter, manufacturer, supplier in Mumbai, Gandhidham - Kandla, Mundra, Sikka, Surat, Kolkata - Haldia, Buz Buj, Paradip, Visakhapatnam - Gangavaram, Fujairah, Dubai, Sharjah, Abu Dhabi, Ruwi Barka Muscat Sohar, Oman, Sudan, Yemen, Nairobi Kenya

BOILER WATER TREATMENT chemicals manufacturer and supplier in INDIA, MUSCAT OMAN, UAE DUBAI, Nairobi

BOILER scale and corrosion control by one shot operation

L GLUTAMIC ACID

Glutamic acid is an amino acid used to form proteins. In the body it turns into glutamate.

This is a chemical that helps nerve cells in the brain send and receive information from other cells. 

Glutamic acid may be involved in learning and memory.

Alias: 

L GLUTAMIC ACID food supplement

Application: 

Glutamic acid often is used as a food additive and flavor enhancer in the form of its sodium salt, known as monosodium glutamate (MSG).

Packing Size: 
25.00 Kg.PWD
Using Procedure: 

Glutamic acid is an amino acid used to form proteins. In the body it turns into glutamate. This is a chemical that helps nerve cells in the brain send and receive information from other cells. It may be involved in learning and memory.

Note: 

The relatively high glutamate levels in some traditional diets suggest that it is a safe food additive. However, anecdotal and scientific evidence indicates that high levels of glutamate and MSG consumption cause adverse health effects.

Safety Accessories: 
Short Description: 
L GLUTAMIC ACID

L GLUTAMIC ACID  manufacturers, suppliers, exporters in Mumbai, Gandhidham, Kolkata, Varanasi, Visakhapatnam, Chennai, Fujairah, Dubai, Canada BC, Barka, Sohar, Muscat, Oman.

Lab chemicals manufacturers, suppliers, exporters in India, UAE Middle East, Barka, Sohar, Muscat, Oman, Canada.

 

L GLUTAMIC ACID  is available in small packing as well as in bulk. Buy premium quality L GLUTAMIC ACID and other lab chemicals from one of the most trusted brands.

L GLUTAMIC ACID food supplEment

Biocide Close Loop

Alias: 

Biocide for Cooling Water

Application: 

Engine Jacket, Chiller Water Circuit, Glycol Brine System, Hot Water Circuit, Engine Coolant, Process chilling and heating etc.
 

Packing Size: 
25.00 Ltr.
Using Procedure: 

Dosage:
The amount of Closed Loop Biocide required to inhibit or remove bio fouling depends on the type of system, application, re-circulating fluid property and plant operating conditions. The specific dosage rates will be specified by the CSL technical representative.
 

Note: 

Advantage / Benefits:

  •     Prevention of Bio-fouling of system.
  •     Avoid plugging of nozzles.
  •     Avoids MIC (Microbiologically Induced Corrosion).
  •     Prevent Water Borne Diseases.
  •     Improve heat loss because living organisms cause rise in temperature of water.
  •     Does not add chloride to the system.
Short Description: 
Closed Loop Biocides, chilled water prevent and eradicate unwanted biological fouling from the system.

Biocide for Cooling Water manufacturer and supplier in Mumbai, Kandla, Kolkata, Dubai, Sharjah, Ajman, Abudhabi Fujairah, Visakhapatnam, Andhrapradesh, Gandhidham, Haldia, Paradip, Muscat Barka Sohar Oman, Kenya Nairobi Africa, Sudan, Yemen

Cooling Water BioCide

KARL FISCHER REAGENT Pyridine Free

The pyridine-free Karl Fischer reagent consists of two solutions, a dissolving agent and a titrating agent. The dissolving agent contains sulfur dioxide and a pyridine substitute in a solvent and is used for taking up the sample to be investigated with respect to its water content.

Alias: 

KARL FISCHER REAGENT Pyridine Free

Application: 

An essentially pyridine-free Karl Fischer reagent useful in the determination of water, comprising a dissolving agent containing sulfur dioxide and a pyridine substitute in a Karl Fischer solvent, and a titrating agent containing iodine in a Karl Fischer solvent, wherein the pyridine substitute is an alkali or alkaline.

Packing Size: 
1.00 Bottle
Using Procedure: 

Karl Fischer Reagent (Pyridine free). single soln for titrimetric determination of water 1 ml reagent ~5 mg water.

Note: 

The analysis of the water content of a sample by Karl Fisher titration can be carried out using a volumetric method or a coulometric one.

Related Products: 
Short Description: 
KARL FISCHER REAGENT Pyridine Free

Comparison of volumetric and coulometric titration cells.

 

In the volumetric technique, which is used to determine higher water contents generally at levels above 5%, the iodine is introduced via a burette or similar dosing system. For lower water content detection, down to ppm levels, the coulometric technique produces the iodine

in-situ by electrolysis. Coulometry improves the Karl Fischer technique by removing the need for reagent calibration and

provides an absolute result in micrograms of water.

Low reagent usage: multiple samples can be analysed with a single charge of reagent which means less waste and less handling of chemicals, good news for Health and Safety

 

 

 Karl Fischer KF Reagent

Karl Fischer KF Reagent A is a general coulometric KF anolyte for use with generator electrodes which incorporate a frit or diaphragm to separate the anode and cathode chambers. Used in conjunction with Reagent C this formulation is supplied in a pack of 8 x 100ml bottles, 8 x 5ml cathode vials, all conveniently located in a single carton.

To conform to ASTM, API, EI, ISO (plus others) methodology for water content determination of oil and petroleum products, the anode regent must be modified with xylene to improve sample solubility and miscibility. Karl Fischer KF Reagent is pre-mixed with xylene, and other solubilizers to eliminate side reactions, so that the operator does not have to store or mix chemicals.

 

 

 

Karl Fischer KF Reagents combine speed and accuracy

VOLUMETRIC COULOMETR K.F. Titration Cell Differences

• Single shot bottles

• Safer to use

• Safer to store

• Low cost

• Faster precondition

• Reduced downtime

• Improved sample miscibility / solubility

• For use with all coulometers

[KARL FISCHER REAGENT Pyridine Free] manufacturers, suppliers, exporters in Mumbai, Gandhidham, Kolkata, Varanasi, Visakhapatnam, Chennai, Fujairah, Dubai, Canada BC, Barka, Sohar, Muscat, Oman.

Lab chemicals manufacturers, suppliers, exporters in India, UAE Middle East, Barka, Sohar, Muscat, Oman, Canada.

 

[KARL FISCHER REAGENT Pyridine Free] is available in small packing as well as in bulk. Buy premium quality [KARL FISCHER REAGENT Pyridine Free] and other lab chemicals from one of the most trusted brands.

Titrators For Accurate Karl Fischer Water Determinations

Mono Ethylene Glycol 230 Kgs

Mono Ethylene Glycol supplier and exporter. MEG is an odorless, colorless, sweet-tasting, viscous liquid.

Alias: 

MEG Glycol

Active Matter: 
99-99.5
Packing Size: 
230.00 Kg.Liq
Short Description: 
PURE Glycol in sealed drum, It is an odorless, colorless, sweet-tasting, viscous liquid.

Mono Ethylene Glycol MEG supplier in UAE Middle East Oman and India. We are MEG supplier and exporter in Fujairah Dubai, Sharjah, Ajman, UAE, Muscat, Barka, Sohar, Oman, Mumbai, Kolkata, Chennai, Visakhapatnam, Gandhidham, Sudan, Yemen, Nairobi, Kenya

MEG

GLYCOLIC ACID

Glycolic acid is a CRYSTAL Solid its characteristic properties is colorless, odorless and hygroscopic and highly soluble in water.
Glycolic acid is a skin care ingredient that is both an alpha hydroxy acid (AHA) and humectant and is widely used for anti-aging, hyperpigmentation, dryness, and acne. Considered the golden standard of AHAs, glycolic acid is a keratolytic meaning it exfoliates dead skin cells from the skin's surface.

Alias: 

GLYCOLIC ACID, Chemical Formula HOCH2CO2H, SKIN CARE PRODUCT

Active Matter: 
99-99.5
Application: 

Glycolic acid should always be applied in the evening, as it makes your skin sensitive to sunlight. Applying it at night gives ample time for it to do its magic without a higher risk or damaging your skin in the sun. But you should still always apply an SPF moisturizer in the morning

Packing Size: 
25.00 Kg
Using Procedure: 

Wash and dry your hands, then open the tube or bottle of glycolic acid. Pour a small amount onto your fingertips and smooth onto your face and neck. Apply in a thin, even layer. Stay away from the thin, sensitive skin around your eyes and don't place the peel solution on your lips.

Note: 

Glycolic acid is an alpha hydroxy acid (AHA) that's widely used for anti-aging, hyperpigmentation, dryness, and acne. Glycolic acid is used to treat the following skin concerns

Short Description: 
Glycolic acid is a CRYSTAL Solid its characteristic properties is colorless, odorless and hygroscopic and highly soluble in water.

GLYCOLIC ACID  manufacturers, suppliers, exporters in Mumbai, Gandhidham, Kolkata, Varanasi, Visakhapatnam, Chennai, Fujairah, Dubai, Sharjah, Abudhabi, Middle East UAE, Canada BC, Barka, Sohar, Muscat, Oman, Sudan, Yemen

Lab chemicals manufacturers, suppliers, exporters in India, UAE Middle East, Barka, Sohar, Muscat, Oman, Canada.

 

GLYCOLIC ACID  is available in small packing as well as in bulk. Buy premium quality GLYCOLIC ACID and other lab chemicals from one of the most trusted brands.

Hydroxyacetic Acid

SULFOLane

Sulfolane is good absorbent of H2S hydrogen Sulfied SOUR GAS. This is the reason why it is used in SHALE and Coal processes.

Alias: 

C4H8O2S

Application: 

Sulfolane is used as an industrial solvent utilized for the extraction of aromatic hydrocarbons from hydrocarbon mixtures and to purify natural gas. Further, it is used in refineries and the petrochemical industry.

Packing Size: 
250.00 Kg.Liq
Using Procedure: 

Sulfolane also widely used  in the manufacture of polymers and electronics, and may be found in pharmaceuticals as a residual solvent used in the manufacturing processes.

Note: 

Miscible with water, acetone, TolueneIncompatible with Strong Oxidizing agents.

Short Description: 
Sulfolane is used as an industrial solvent utilized for the extraction of aromatic hydrocarbons from hydrocarbon mixtures and to purify natural gas. Further, it is used in refineries and the petrochemical industry.

Sulfolane supplier in Mumbai, Kandla, Chennai, Ennore, Visakhapatnam, Kolkata, Haldia, Paradip, Fujairah, Dubai, Sharjah, Abudhabi, Ajman, Muscat Barka Oman

We also keeping ready stock of following chemicals : 

1. Hydrazine Hydrate 

2. Monoethanolamine 

3. Diethanolamine 

4. Sulfolane 

5. Morpholine 

6. Potassium carbonate 

7. Triethanolamine 

8. Cyclohexylamine 

9. Ethylene Diamine 

10. Trichloroethylene 

Sulfolane Solvent

Chlorhexidine Gluconate

Chlorhexidine, also known as chlorhexidine gluconate, is a disinfectant and antiseptic that is used for skin disinfection before surgery and to sterilize surgical instruments. It may be used both to disinfect the skin of the patient and the hands of the healthcare providers. As per WHO World Health Organization  ALCOHOL HAND RUB is beneficial against VIRUS, Bacteria..

Alias: 

Biguanide, 1,1- Hexamethyle and Digluconate (5-(p-Chlorophenyl)-Digluconate ‘1.6-nis (5(p-Chlorophenyl))- Digluconate

Application: 

We are manufacturer and can offer you our Chlorhexidine Gluconate in 50ltr jars and 200ltr barrels and the same can be repacked in smaller packs and sold in your local market.

Chlorhexidine Gluconate is a germicidal mouthwash that reduces bacteria in the mouth. Chlorhexidine gluconate oral rinse is used to treat gingivitis (swelling, redness, bleeding gums). Chlorhexidine gluconate is usually prescribed by a dentist.

Packing Size: 
5.00 Ltr.
Using Procedure: 

Usual Adult Dose for Gingivitis

Usual dose: 15 mL (approximately 0.5 fluid ounces) swished in the mouth undiluted for 30 seconds and spit out 2 times a day

Usual Adult Dose for Mucositis

Usual dose: 15 mL (approximately 0.5 fluid ounces) swished in the mouth undiluted for 30 seconds and spit out 2 times a day

Usual Adult Dose for Periodontitis

Usual dose: 2.5 mg (1 periodontal chip) inserted into a periodontal pocket with probing pocket depth (PD) of 5 mm or more every 3 months

Usual Adult Dose for Skin Disinfection, Preoperative

Chlorhexidine Gluconate 0.5% Topical Solution (Towelette)

Chlorhexidine Gluconate 0.75% Topical Solution/Hand Wash:
-Wet hands with water, then apply approximately 5 mL into cupped hands and wash vigorously for 30 seconds. Personnel should wash and dry hands thoroughly.

Note: 

We have very good discount schem for given quantity :
Chlorhexidine Gluconate in 5ltr jar for 200ltr minimum order quantity 
Chlorhexidine Gluconate in 20ltr jar for 200ltr minimum order quantity
Chlorhexidine Gluconate in 50ltr jar for 200ltr minimum order quantity
Chlorhexidine Gluconate in 200ltr drum for 200ltr quantity
Chlorhexidine Gluconate in 50ltr jar for 1000ltr order or above
Chlorhexidine Gluconate in 200ltr jar for 1000ltr order or above
Delivery – Immediate dispatch from ready stock upto 10,000 ltrs

GOOD FRAGRANCE, GOOD MOISTURIZING, EXCELLENT VIRUS SECURITY GUARANTEED!

Short Description: 
As per WHO World Health Organization ALCOHOL HAND RUB is beneficial against VIRUS, Bacteria.

Related Substance by HPLC

Impurities                          N.M.T 0.3%  0.014%
Impurities L  N.M.T 0.2%  0.109%
Impurities Q N.M.T 0.2%  0.025%
Impurities N N.M.T 1.0% 0.098%
Impurities B N.M.T 0.2% 0.038%
Impurities F N.M.T 0.2% 0.011%
Impurities A N.M.T 0.4% 0.017%
Impurities H N.M.T 0.5% 0.226%
Impurities O+I N.M.T 0.4% 0.026%
Impurities J N.M.T 0.4% 0.023%
Impurities K N.M.T 0.4% 0.040%
Unspecified Impurities N.M.T 0.1% 0.090%
Total  Impurities  N.M.T 3.0% 0.909%

Chlorhexidine gluconate manufacturer and supplier in Fujairah, Muscat, Oman, Dubai, Sharjah, Abudhabi, Ajman, Mumbai, Kolkata, Gandhidham, Surat, Chennai, Visakhapatnam, Sudan, Nairobi Kenya Africa, Yemen

Chlorhexidine Gluconate

Chlorhexidene Gluconate

Hydrometer

Place the hydrometer into water, and let it flow freely in the water...

Alias: 

Glass Float Hydrometer, Hydro Meter

Application: 

Hydrometer provide High Accuracy to get Density, Specific Gravity of liquid.

Packing Size: 
1.00 No
Using Procedure: 

Density Meters Measures liquid concentration.

Note: 

Seawater Hydrometer specialized for measuring the percentage of salt in seawater and Specific Gravity of the water and mix water.

Article News: 
Short Description: 
Place the hydrometer into water, and let it flow freely in the water

Seawater Hydrometer supplier in Dubai, Sharjah, AbuDhabi, Ajman, Fujairah UAE Middle East, Muscat Oman, Mumbai, Kandla, Chennai, Visakhapatnam, Kolkata, Haldia, Howrah.

 INSTRUCTIONS FOR USE
1. A clean, representative sample of the supporting water should be obtained by means of a sampling can or other suitably designed sampling apparatus. A sample of at least 1 liter will help to ensure that the temperature and density do not change unduly between the collection of the sample and taking of the readings. The depth of water in the container must be sufficient to allow at least 25mm clearance between the bottom of the hydrometer and the bottom of the hydrometer and the bottom of the container. The internal diameter of the container or jar should be at least 50 mm.
2. The number of samples to be taken, also at which depths and at which positions outside the vessel they should be taken, may be important according to the circumstances.
3. Readings may be taken by lowering the hydrometer into a suitably shaped sampling apparatus or by transferring the water to a suitable glass test jar. If a metal or other non-transparent container is used for taking readings, ensure that it is full to the brim. If a glass test jar is used, it should preferably be rinsed first, so as to avoid undue temperature changes. The container or test jar should be shielded from draughts, which may affect the readings.
4. The reading must be taken in the sampling apparatus or glass test jar as rapidly as possible Undue delay in taking the reading could result in temperature changes leading to inaccurate results. In case of doubt, a repeat sample should be taken in order to verify the first observation
5. Ensure that the stem of the hydrometer and the surface of the water sample is free from grease and oil since the accuracy of the readings could be adversely affected
6. Hold the hydrometer vertically by the top of the stem and gently lower it into the water sample until it floats freely
7. Take the hydrometer reading where the level liquid surface meets the graduated scale.

CORRECTIONS TO HYDROMETER READING
1. For ydrometer the appropriate corrections should be applied.
2. For most Draft Survey purposes, no further corrections to the readings are needed.
Reading is most correct when the glass hydrometer is used at a temperature of 15°C. If immersed in water at temperatures higher or lower than 15°C, the instrument will expand or contract so that, for precise laboratory work, a small correction would be applicable However, for Draft Survey work, it should be noted that the ship itself will normally expand or contract according to the temperature of the water in which it is rating. The corrections required to compensate for these changes in volume are of opposite signs and tend to compensate for each other. As it is not practicable to calculate any temperature corrections for the ship, for most Draft Survey purposes no correction should be applied for the expansion or contraction of the hydrometer glass

Hydrometer Density supplier in India UAE Middle East Gulf Muscat Oman Nairobi Kenya.

Density Meter

stock-clearance.png