Boiler Chemicals-42

ACID Neutralizer Amine

RXSOL-24-1461-180 ACID Neutralizer Amine  is a colorless to pale yellow, hygroscopic viscous liquid with slight ammoniacal odor. We are manufacturer and supplier and exporter of pH Neutralizer.

Alias: 

ACID GASES Neutralizer

Application: 

RXSOL-24-1461-180 ACID Neutralizer Amine is used as intermediate in the manufacture of surface active agents, textile specialties, antirust compounds, waxes, polishes, herbicides, petroleum demulsifies, cement additives and cutting oils.

It also finds extensive use in the manufacture of Synthetic resins, as a solvent for casein, shellac and dyes, for increasing the penetration of organic liquids into wood and paper in the production of lubricants for textile industry and in making emulsions with mineral and vegetable oils, paraffin and waxes.

Packing Size: 
210.00 Ltr.
Short Description: 
pH Neutralizer Amine is a colorless to pale yellow, hygroscopic viscous liquid with slight ammoniacal odor. We are supplier and exporter of TEA.

RXSOL pH Neutralizer is a clear colorless liquid with a strong ammonia to fish-like odor.Vapors irritate the eyes and mucous membranes. Produces toxic oxides of nitrogen when burned.

Mixes easily with water.

MOLECULAR formula : N(CH2CH3)3

ANTI-LIVERING AGENT(An anti-livering agent is a coating additive used to prevent the increased consistency of a precipitate from forming on a metal surface due to polymerization or other chemical reactions) FOR UREA & MELAMINE BASED ENAMELS; RECOVERY OF GELLED PAINT VEHICLES; CATALYST FOR POLYURETHANE FOAMS; FLUX FOR COPPER SOLDERING.

More application :

Adhesives : Hot melt/Polyesters, Urea/Phenol/formaldehyde, Asphalt/Bituminous, Refractory binders.

Agricultural Chemicals : Neutralize, Algaecide lye peeling assist.

Antistatic Agents : Polyethylene, Polypropylene, Polyamide Polyester, Cotton Fibers, Carpet Backings.

Cement Concrete : Grinding Aid, Fluidity improver strength improver, Mechanical Stability agent, Workability improver, Set Accelerator, Whiteness improver.

Coatings : Water-borne, metal, Glass/film solvent free/Accelerators, Electropheretic.

Coating Remover: Penetrant/Accelerant

Corrosion Inhibitor : In Lub Oils, in Hydraulic Fluids, Coolants with Bactericidal effect, for Aluminium, for Ferrous Metals.

Electroless Plating : Copper

Electroplating : Silver, Tin, Zinc, Cadium, Copper-Nickel, Tin-Nickel, Tin-Cobalt Alloy.

Expoxy: Hardner.

Fuels : High Octane, .Propellent

Inks, Printing : Diazo Dyes, Inks.

Lithography: Developer

Metal Working Cleaning Lubricating : Metal Forming Lubricant, aqueous Lubricant, Cutting Fluid, Cleaners/Degreasers, Etchant.

Mining : Floatation, Dust control

Paint / Pigments : Adhesion improver Thixotropic additive, TiO2 dispersant, Grinding Aid, Pigment dispersant

Petroleum-Coal : Drilling Mud stabilizers, thermal oxidation stabilizers, chemical washes, Tertiary recovery, surfactant, Demulsifier, Oxygen scavenger, Gelling Agent-Fuel.

Polymers : Thermal oxidation stabilizers, Polymerization initiator, Cross-linker, Plasticizer, Chain transfer agent.

Rubber Processing : Vulcanization Accelerator, Stabilizer/ Antioxidant, Activater-filled rubber Dispersant, Chain termination agent.

Soldering Flux : Penetrent.

Textiles : Finishes-Dispersant, Cross linker, Softeners, Lubricant, Bleaching aid, Dye-neutralizers, Fixation catalyst, Extruder cleaner.

Urethanes : Polyol, Chain extender cross linking/curing agent, Catalyst, Modifier, Solubilizer, Degradation waste foam.

Wood Pulping : Swelling Agent.
 

Use industrial and consumer based:

Triethylamine is an important commercial chemical. It is used as a curing catalyst in foundry molds (foundry is a factory in which metals are cast into different shape by keeping in a container or mold after removing which the metal solidifies and gains that shape), and in particle-board adhesives. It is used for the precipitation and purification of antibiotics. It is used for the production of polycarbonate resins. Triethylamine is found in tobacco smoke, two household use products (floor finish, stump and vine killer) and is approved for use in food and food packaging.

pH Neutralizer Amine supplier and keeping ready stock at Chennai - Ennore, Vizag - Visakhapatnam, Kolkata - Haldia, Mumbai - MIDC, Surat - Kandla, Fujairah - Sharjah - Abu Dhabi, Dubai, Sudan, Muscat Ruwi Barka Oman, Nairobi AFRICA, Sudan, Yemen

RXSOL-24-1461-180 ACID Neutralizer Amine pH Neutralizer Amine  ready stock in various size and packing. pH Neutralizer is chemically alkaline amine based products which is also used as surfactant emulsifier and neutralizing acidic value to adjust pH chemical nature. TEA most commonly used in Fragrance Ingredient; pH balancing Adjuster; As a Surfactant - Emulsifying Agent; also as BUFFERING and MASKING agent.

pH Neutralizer Amine Acid Gases

Marine Descaler

LIME Marine is a safe, biodegradable marine descaler developed to dissolve problematic fouling mediums including calcium, rust, mussels, barnacles, tiger shells and other scale formed mineral deposits that hinder the performance of vital water systems. RXLYME Marine is formulated to meet the demands of today's water systems.

Alias: 

RYDLYME Marine DESCALER, Desacling agent for Marine Diesel Engine Fresh water cooler, Marine Biodegradable Descaler for Titanium and SS TUBES 25 Ltr pack

Application: 

This safe and simple solution effectively dissolves rock-like scale deposits that contaminate your water-cooled marine equipment. LIME Marine is used at ambient temperature and then circulated to bring the solution in contact with the accumulated minerals. The reaction results in a slight foaming or bubbling action, indicating the deposits are actually dissolving into solution, and then simply water flush away! These scale deposits, along with zebra mussels and tiger shells, damage your equipment and reduce your water system performance. Historically, these problems have been addressed via harsh acids, mechanical methods, ion exchange, polyphosphates, permanent magnets and electronic conditioning. If your vessel is heat exchanger cooled, keel cooled, or radiator cooled, try LIME Marine and ride the waves with maintenance superiority.

Packing Size: 
25.00 Ltr.
Using Procedure: 

LIME Marine should be used as directed and at any temperature within the operating limits between 0°F / -18°C and 180°F / 82°C. If the solution does freeze, slush or thicken at the lower operating temperatures, and then thaws, there will be no performance reducing results. Please consult the manufacturer when temperatures above 180°F are encountered.
RXLYME Marine should be applied at ambient temperatures with no heating required. The solution is exothermic, but does not develop a substantial increase in temperature while dissolving water scale, rust, mussels, barnacles, zebra mussels, tiger shells and other water formed deposits.

Note: 

Advantage :

  • The solution does not deteriorate, oxidize, saponify, thicken or lose effectiveness for at least five years.
  • The solution is of a pleasant or characteristic odor, very similar to cherries, and does not exude any obnoxious or toxic vapors. In rare instances, problematic vapors may occur when encountering high concentrations of sulfur or chlorine. Please contact the manufacturer before proceeding under these circumstances.
  • The solution does not require neutralizers and it is free rinsing with water.
  • The solution has the ability to dissolve deposits from some equipment while in operation and without shutdown, if auxiliary coolers are incorporated.
  • The solution has the properties to be mailed or shipped by any private or commercial carrier without restrictions. Air carriers for emergency deliveries may ship LIME Marine via next day air.
  • No Need circulate material for more than a four-hour period without consulting the manufacturer. Most LIME Marine cleaning applications can be accomplished within an average of two to four hours.Please use material only as directed.

This allows the solution to be water flushed down normal plant sewers. Check with local ordinances and regulations in your area prior to disposal.

Our company is holding no-1 RXSOL Brand Descaling Boilers Chemical as a  Descaling Chemicals Manufacturers, Descaling Chemicals Wholesale Suppliers, Descaling Chemical suppliers, dealers, distributors India and Descaling Chemical exporters for UAE. 

We have supply network in Rabale, Navi Mumbai, Mumbai, Surat, Kandla, Gandhidham, Mundra, Sikka, Chennai, Ennore, Vizag, Visakhapatnam, Kakinada, Kolkata, haldia, Paradip, Fujairah, Dubai, Middle East

Short Description: 
LIME Marine is a safe, biodegradable marine descaler developed to dissolve problematic fouling mediums including calcium, rust, mussels, barnacles, tiger shells and other scale formed mineral deposits that hinder the performance of vital water systems

LYME MARINE is scale dissolving chemicals. Lyme marine descaler effectively cleans fouling mediums including calcium, rust, mussels, barnacles, tiger shells and other scale formed mineral deposits that hinder the performance of vital water systems.

LIME Marine has the ability to dissolve approximately 1 Kg of calcium carbonate scale per 3.75 Ltrs in concentrated form. If the LIME Marine is diluted, it will still dissolve 1 Kg of carbonate scale per 3.75 Ltrs, but will require additional circulating time.
The concentrated solution can be held safely in the open hand without deleterious affects. It will however cause a stinging sensation when contact is made on an open wound or cut. If this occurs, simply rinse thoroughly with soap and water.

#MarineBiodegradableDescaler_SoharOMAN
#DescalerFORTitaniumTUBES_dubaiUAE
#ScaleREMOVER_Sharjah
#DescalingCHEMICAL_barkaMUSCAT

 

LIME Marine  is non-corrosive, non-hazardous, and biodegradable. With the reduction of labour and operating costs, downtime, and no installation costs, accompanied with the heavy duty cleaning power, LIME Marine keeps your vessel at sea generating revenue.

LIME Marine manufacturer and supplier in Mumbai, Kandla, Vizag - Visakhapatnam, Surat, Chennai - Ennore, Kolkata - Haldia - Paradip, Fujairah - Dubai, Abu Dhabi - Sharjah, Muscat Barka RUWI,  Oman Sohar, Nairobi Kenya Uganda Africa

Desacling agent for Marine Diesel Engine Fresh water cooler

TURBOCLEAN HeavyDuty Hydrocarbon

The blend of Non-ionic surfactants, Hydrocarbon solvents, and many powerful heavy-duty ingredients for effectively on-line fired wash cleaning of gas turbine compressors. TURBOCLEAN HeavyDuty Hydrocarboncon is a concentrated powerful cleaner for the compressor section of industrial, Marine aviation gas turbine engines. TURBOCLEAN HeavyDuty Hydrocarbon also specialized in on-line fired wash cleaning of gas turbine compressors.

Alias: 

FIREWASH SB, TURBOTECT 2020

Application: 

Gas Turbine Compressor Cleaning TURBOCLEAN HeavyDuty Hydrocarbon RXSOL  solvent-based cleaners  for effective Degreasing, Cleaning of oil deposits and Decarbonising the surface of gas turbine compressors. TURBOCLEAN HeavyDuty Hydrocarbon is SOLVENT based powerful cleaner where as water-based detergents are much less effective.

Packing Size: 
220.00 Ltr.
Using Procedure: 

By spray ring or lance in either starter-driver (off-line) or fired (on-line) wash as directed by the engine manufacturers, in the quantities recommended in the engine manual. It is essential during hot wash that the cleaner should leave as little ash residue as possible to avoid blocking turbine blade cooling holes. 

Mix One Part of TURBOCLEAN HeavyDuty Hydrocarbon  with 4 PARTS of DI Water for On-line cleaning.

Note: 

Appearance
Clear pale straw coloured liquid with a mild pleasant odour.

Solubility
Completely soluble in water. No agitation required.

Compatibility
Not corrosive or detrimental to any of the materials normally used in gas turbine engines or aircraft components. No adverse effect on synthetic turbine oils.

Short Description: 
Specialized Heavy-Duty Hydrocarbon solvent-based chemical for on-line fired wash cleaning of gas turbine compressors

TURBOCLEAN HeavyDuty Hydrocarbon Gas Turbine Compressor Cleaning Fluid exporter and supplier in Mumbai, Dubai, Kandla, Chennai, Muscat, Visakhapatnam, Kolkata, Fujairah, Sharjah, Abu Dhabi, Muscat Barka Ruwi, Oman, Nairobi Kenya Africa, Sudan, Yemen

Heavy-Duty Hydrocarbon Solvent-based for on-line fired wash cleaning of gas turbine compressors

Battery DEIONIZED Water

Alias: 

Battery Grade Purified Water, Battery Water 210 Ltr, DEIONIZED Water for POWER SUPPLY BATTERY

Active Matter: 
100
Application: 

Different grades and types of distilled water offered by us is formulated employing highly advanced cold process technology.

Commercial Distilled Water:

  • Distilled Water 3 in 1 ( Distilled Water 3 In 1 can be used in:::-
     For top up in inverter and all types of batteries
    Add with coolant in radiator (as per ratio recommended)
    Add in wiper tank of a car for cleaning windshield
  • Aquarium Water
  • Battery Distilled Water
  • Windshield Wiper Water
  • Distilled Water For Home
  • Industrial Water
  • Distilled water for Pathology Laboratory
  • Radiator Coolant Water
  • SPA & Saloon Distilled Water
Packing Size: 
210.00 Ltr.
Using Procedure: 

MAINTENANCE SCHEDULE ::: The maintenance schedule given here is divided in daily, weekly, monthly and yearly maintenance. The actions to be taken, checks and recording required are given herewith.
A.DAILY MAINTENANCE
1. A daily general maintenance should include a check and record of the following :
2. Overall float voltage measured at the battery terminals
3.Charger output current and voltage
4.Specific gravity, voltage and temperature of pilot cells.

B.WEEKLY MAINTENANCE
A weekly maintenance should include all the items mentioned in “daily maintenance” and the following :
1. Check electrolyte level of all cells and if required, top-up with battery grade water conforming to IS 1069. Never use metal vessels for topping up because of the risk of electrolyte continuation and accidental short circuit.
2. Visually check the conditions of each cell and battery bank. If abnormal or very high amount of sulphation on the terminals or connectors are observed, take immediate action in removing them.
3.Visually check the cleanliness of battery, battery stands and battery room area for accessibility, cell integrity and acid leakage.

C.MONTHLY MAINTENANCE
1. A monthly maintenance shall include all checks listed under “daily” and “weekly” maintenance schedule and also the following:
2.Check and record specific gravity, voltage and temperature of all cells in the battery bank.
3.Adjustment of specific gravity by addition of battery grade water is to be done only after charging and under skilled supervision (Never use acid for this purpose unless specifically suggested by manufacturer). After adjustment of specific gravity, charge the battery at a voltage around 2.4 volts per cell for a period of 2 hours for mixing of the electrolyte properly.

D.QUARTERLY MAINTENANCE
A quarterly maintenance shall include all checks listed under “daily”, “weekly” and “monthly” maintenance schedule and also the following :
1. Check and record specific gravity, voltage and temperature of all cells in the battery bank.
2.If the specific gravity of most of the cells are found to be lagging by an average of 10 to 15 points, the battery bank would call for an equalizing charge at a current equivalent to 3% - 5% of its rated value for 6-10 hours to restore the state of charge to full..
3.The temperature of the electrolyte normally is higher than the ambient. But for a bank, unless it has undergone a discharge within previous 24 hours, the electrolyte temperature should lie within 3
5 deg. C higher than the corresponding ambient temperature. In case of a deviation from this range, the charger needs to be checked for its quality of power output in terms of the ripple contents in the charging voltage and current. Corrective action should be immediately taken to avoid any deterioration in the battery bank due to this anomaly

E.HALF YEARLY MAINTENANCE
A half yearly maintenance shall include all checks listed under “daily”, “weekly”, “monthly” and “quarterly”
maintenance schedule and also the following :
1.Remove all corrosion product and clean connector thoroughly. Use enough amount of petroleum jelly on the connectors to prevent farther corrosion and put back shrouds in place.
2. Check the tightness of fasteners on inter-cell, inter-row and inter-tier connections to prescribed torque values as suggested by manufacturer. If required, tighten the connections to the required torque value .

F.YEARLY MAINTENANCE
A yearly maintenance should include all items listed under 'daily', 'weekly' and 'monthly' maintenance schedule and also the following : Discharge the battery at C10 current for 10 hours followed by a constant current recharge.
The charging to start at the “starting rate” as mentioned in the product catalogue for the respective size till the cell voltage
reached 2.36 volts per cell followed by charging at “finishing rate” pertaining to the specific size of the battery as mentioned in manufacturer's catalogue. The charging to be stopped when the cell voltage and specific gravity readings are constant for four consecutive half hourly readings. The expected end-of-charge voltage is of the order of 2.7 2.75 volts per cell.
During charging it has to be ensured that a minimum Ah input of 125% of the previous discharged Ah is administered to the battery.
The temperature during charging should not increase beyond 450 C. In such cases, the charging to be stopped and the cells to be allowed to cool down till 400 C when the charging can be resumed. The timings are to be noted so that the duration of charge can be compensated accordingly to ensure that the minimum Ah input requirement is fulfilled. After the charging is over, gravity and level adjustments are to be carried out after a rest of 4 hour.
The battery bank, then, is to be given an equalisation charge at a current equivalent to 3% - 5% of rated C10 capacity for 12-24 hrs. The battery bank can be given back to the system after the equalising charge is over
.
 

Note: 

GENERAL :

In order to ensure safety , it is essential to operate and maintain your batteries in accordance with the recommendations in this booklet.

a). ACID : Batteries contain dilute sulphuric acid which is poisonous and corrosive. It can cause burns on contact with skin and eyes. If acid is split on skin or clothing, wash plenty of clean water. If acid gets in to the eyes wash well with plenty of clean water and get IMMEDIATE MEDICAL ATTENTION.

b)GASES : Batteries can give off explosive gases. Keep sparks, flames and lighted cigarettes away from battery and battery room. Ensure connections are tight before switching on, using only insulated tools. Areas where batteries are kept or charged must be adequately ventilated.

c).ELECTRICITY :

Use only insulated tools to make connections to a battery. Check the circuit to ensure it is safe before making a connection to the battery. Before working on a battery , always remove personal metal effects, such as rings, watches, bracelets, necklaces, etc.

ALWAYS PROTECT THE EYES.

e)ERECTION :
Erection and commissioning of batteries to be done in accordance with separate instructions provided by manufacturer.

FLOATING BATTERY SYSTEMS : In a floating battery installation the charger , battery and load are connected in parallel. The charger supplies the load current continuously whilst the battery remains in a charged condition, immediately capable of supplying the load should the main supply be interrupted.

CONDENSED INSTRUCTIONS

Top up all cells regularly with distilled or deionised water.

Keep the electrolyte level between the red and green mark, preferably near the green mark, etched on the transparent level indicator

.

If,before topping-up, the electrolyte level had fallen below the red mark, it is advisable to give the battery acharge for approximately ½ hour above 2.3 volts per cell after addition of battery grade distilled water in order to mix the electrolyte. Keep battery and surroundings clean and dry

.

Ensure bolted connections are tight. Keep connectors, pillars and bolted connections covered with petroleum jelly for protection against corrosion.

Take every precaution to avoid risk of explosion of gases particularly during charge.

Never smoke or use a naked flame near the battery, or in the battery room or take any action which could cause an electric spark.

Ensure that charging equipment maintains the battery at the correct voltage.

Examine all cells at regular intervals.

Action should be taken to restore any “out of step” cells to a fully charged condition.

The room in which the battery is housed should be well ventilated and its temperature as moderate as the climate will allow

.

The temperature of electrolyte should preferably never exceed 380C

 

FLOATING

The method of operation known as “floating” means that the charger, the battery and the load are connected in parallel.

The battery should be held constant at a voltage between 2.23 to 2.27 volts per cell, so that the battery will normally be maintained in a fully charged condition. The voltage to be maintained based on the ambient temperature as detailed in TableI.

 

Temperature Float Voltage
<5 deg. C 2.270.02 vpc

200C to 350C

2.250.02 vpc

360C to 450C

2.230.02vpc

TABLE-I

The charger on a floating system should have a current rating sufficiently high to ensure that the battery does not become discharged during prolonged periods of operation. The current rating of the charger should be higher than the normal continuous loads of the system, so that the battery only supplies the short duration peak loads when the current required is greater than the

charger output. The voltage output of the charger may be regulated either automatically, or manually .The automatic type of constant voltage charger will maintain the pre-set steady voltage indefinitely, if used within its rated output. With the manual type of charger, however, care should be taken to keep the voltage level correct at all times, particularly if loads vary appreciably

, by adjustment of the voltage control.

BOOST CHARGING

The battery should be recharged as soon as possible after any discharge, amounting to more than 5 to 10% of the rated capacity of the cells. A reference to the specific gravity of electrolyte in the pilot cell will indicate when a charge should be given. Should the fall in gravity of the pilot cell from the normal fully charged value, be greater than the allowable specific gravity drop, then the battery should receive a boost charge.
Operate the charger in accordance with the separate charger instruction, so as to supplya charge current to the battery. The initial “starting rate” charging current can be any value up to two times the “finishing rate” of charge, as given in the Appendix. The voltage of the battery will rise as the battery becomes charged. When the battery voltage reaches a value equivalent to 2.36 volts per cell, the charge current should be limited to a maximum of the “finishing rate” of charge. Where automatically regulated charges are employed, the charge current may not be under manual control, but the current output of such charges should not greatly exceed the finishing rate of charge, when the cells are gassing. Charging should be continued, taking specific gravity and voltage readings on the pilot cell, at half hourly intervals, until the readings become sensibly constant over a period of 2 hour

.

After the charging is over, the specific gravity of electrolyte has to be adjusted, if required, to a value indicated by the manufacturer by addition of demineralised water only. Use well calibrated hydrometer for the purpose of specific gravity measurement with a tolerance of +/- 0.005 points. Never use acid for level adjustment of cells. The type of charger and the controls provided on it, will determine the procedure to be carried out in order to charge the battery. The manufacturer's charger instructions should be referred to if in doubt

PILOT CELL ::: Select one cell of the battery as a 'pilot cell. For batteries containing more than 60 cells, select one pilot cell
for each 60 cells. Any variations in specific gravity of the electrolyte in the 'pilot' cell(s) will be indicative of the state of charge
of the whole battery. Keep the electrolyte level between the red and green mark, preferably near the green mark, etched on the
transparent level indicator by adding distilled or deionised water when required. After topping up,
it is preferable to give the battery a charge for approximately ½ hour, above 2.3 volts per cell. This will mix the electrolyte and
prevent water from stratifying at the upper level.

5.GENERAL INFORMATION
1. Specific gravity: The specific gravity of the electrolyte in fully charged cells should be 1.200+/-0.005 at 270 C. During the course of years there may be a slight fall in the maximum specific gravity values obtainable at end of charge, but acid should never be added except on the recommendations of the manufacturer.
2.Topping up Due to evaporation, and gassing on charge, water is lost from the electrolyte, and the level gradually falls.
Water must be added at intervals to bring the electrolyte to the correct level. Do not allow the levels to fall below the red mark.
The water used for this topping-up operation must be pure and should be demineralised and conforming to IS 1069 Never use metal vessels for storing or dispensing the topping-up water.
Water should preferably be added below the surface of the electrolyte, by use of a rubber syringe or plastic funnel. This helps to mix the water with the electrolyte. It will also help to assist mixing by having the battery on charge, with all cells gassing, either during, or soon after topping-up.
3.Preservation Keep the battery and surrounding clean and dry.
Wipe down the cells with a clean soft cloth dampened with clean water, if necessary, a small amount of mild detergent may be added to the cleaning water to remove any greasy film. Ensure bolted connections are tight. Keep connectors, pillars and bolted connections covered with petroleum jelly for protection against corrosion. Should any corrosion of the connectors occur because of spilt acid etc. carefully remove corrosion products, thoroughly clean and neutralize with alkali solution or dilute ammonia.
Dry the affected parts and liberally coat with petroleum jelly to protect from further corrosion. Care should be taken to ensure that the neutralizing solution does not enter the cell.
4.Temperature correction The specific gravity of the electrolyte varies with temperature. Any reading observed on the hydrometer should therefore be corrected as follows: For every 100 , above 150 C, add 7 point (0.007 specific gravity) to the specific gravity as read on the hydrometer
Similarly, for each 100 C, below 150 C, subtract 7 point (0.007 specific gravity) as read on the hydrometer

 

Short Description: 
For top up in inverter and all types of batteries also Add with coolant in radiator (as per ratio recommended) , and to keep stain free glass add in wiper tank of a car for cleaning windshield

Battery DEIONIZED Water Distilled Water Battery grade manufacturer and supplier in Mumbai, Gandhidham, Visakhapatnam, Chennai, Ennore, Kolkata Haldia, Fujairah, Dubai, Sharjah, Abudhabi. RXSOL Brand Distilled Water Battery Grade largest manufacturer and supplier in Muscat Barka Ruwi Oman, Nairobi Kenya Sudan Yemen

Battery Water

Electrolyte KOH Liquid

Electrolyte Liquid is a medium containing ions that is electrically conducting through the movement of those ions, but not conducting electrons. This includes most soluble salts, acids, and bases dissolved in a polar solvent, such as water. Upon dissolving, the substance separates into cations and anions, which disperse uniformly throughout the solvent. Solid-state electrolytes also exist. In medicine and sometimes in chemistry, the term electrolyte refers to the substance that is dissolved.

Alias: 

Electrolyte, KOH SOLUTION, Potassium Hydroxide Solution in Distilled Water, Electrolites for Nickel Cadmium Batteries

Application: 

In science, electrolytes are one of the main components of electrochemical cells.

Packing Size: 
300.00 Kg.Liq
Note: 

Electrically, such Electrolyte liquid is neutral. If an electric potential is applied to such a solution, the cations of the solution are drawn to the electrode that has an abundance of electrons, while the anions are drawn to the electrode that has a deficit of electrons. The movement of anions and cations in opposite directions within the solution amounts to a current. Some gases, such as hydrogen chloride (HCl), under conditions of high temperature or low pressure can also function as electrolytes. 

Short Description: 
Potassium Hydroxide Solution in Distilled Water suitable for Nickel Cadmium Batteries

Electrolyte Liquid manufacturer and supplier in Mumbai, Kolkata, Chennai, Visakhapatnam, Surat, Kandla Gandhidham Gujrat, Fujairah, Ajman, Dubai, Sharjah, Abudhabi, UAE GUlf, Muscat Barka Ruwi Oman, Sudan Yemen, Nairobi Kenya

Potassium Hydroxide Solution

Sodium Chlorite Technical Grade 25%

Packing Size: 
1250.00 Kg.Liq
Short Description: 
SodiumChlorite is also used for water treatment purpose.

Sodium Chlorite Technical Grade 25% manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai, Sharjah, UAE, Gulf, Middle East, Muscat Oman, Kenya Africa. Get the best quality of Sodium Chlorite Technical Grade 25% at a competitive price from us. We have ready stock of Sodium Chlorite Technical Grade 25% in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

Antifreeze Coolant Green

RXSOL ANTIFREEZE GREEN Corrosion Inhibitor

Introduction

Alias: 

Anti Freeze Coolant Green, Universal Antifreeze Coolant 50

Active Matter: 
98 - 99%
Application: 

Solution Strength :
25 Ltrs RXSOL-16-4020-020 : 75 Ltrs Water gives freezing protection up to -140C  "or" 25% solution (1 part anti-freeze to 3 parts water)
For extra cold / winter climate , increase to a 33% solution (1 part anti-freeze to 2 parts water) to give freezing protection down to -170C.

 

 

Packing Size: 
25.00 Ltr.
Using Procedure: 

EYES : Irrigate copiously with clean, fresh water for at least 15  minutes. Seek medical advice.
SKIN :  Wash  immediately  with  plenty  of  water.  Remove  contaminated   clothing.  If  irritation  persists  seek  medical attention.  Wash  contaminated  clothing  before  using  them.
INHALATION : Remove to fresh air. If breathing is irregular seek medical advice.
INGESTION :  Obtain  immediate  medical  attention.  Induce  vomiting  only  if indicated  by  the  doctor.  Never  give anything  by  mouth  to  an  unconscious  person.

 

Note: 

Coolant Green  is an inhibitor concentrate/chemical which is added to the cooling water of internal combustion engines in cases in which the coolant does not need to be protected from freezing. It efforts excellent protection against cavitation and corrosion to all metals and alloys that are used in cooling systems.It is especially appropiate for the use in heavy-duty engines such as those used in trucks,  ships and lokomotives.

• High performance corrosion inhibitor
• Being a nitrite free product it is compatible also with zinc - coated piping
• Easy control test with refractometer.

Short Description: 
Universal Antifreeze coolant 50% for cooling water systems , It is a Very effective blend of GLYCOL classified chemicals along with CORROSION inhibitor to protects all engineering precious metal including aluminium . Its chemically treated layer protect radiators and

At concentration of 10% by volume, Coolant Green Antifreeze affords excellent protection against cavitation and corrosion to all metal and alloys which are used in cooling system, such as aluminium, ferrous and yellow metals.

Antifreeze Coolant or Radiator Coolant is used by all vehicles for heat transfer. Antifreeze Coolant should be efficient in transferring the heat as well as preventing scale & corrosion of the radiator and the engine cooling system. Antifreeze Coolant is antifreeze during the winter due to low freezing point and an anti boiling during the summer season due to high boiling point.

 

Antifreeze Coolant or Radiator Coolant helps the engine to give optimum performance. All Antifreeze Coolant is based on Ethylene Glycol. RXSOL is selling Antifreeze Coolant.  RXSOL meets the international JIS - K - 2234 or OEM specification & Supersedes.

MAXIMUM PROTECTION UNDER WIDE OPERATING TEMPERATURE RANGE

 

Fully formulated ethylene glycol base Coolant that has improved heat transfer ability.

Organic Acid Technology providing superior corrosion and rust protection leading to reduced maintenance.

Meets industry leading specifications – JIS K 2234 Class 2, ASTM D3306, BS 6580:2010.

The coolant should be prepared with water that is clean but not too hard. The following types of water are unsuitable: sea water,mixture of sea water and fresh water, salt water and industrial waste water. The analytical values of the water should be within the following limits :
Water hardness   : 0 -    100 ppm
Chloride contents: max 100 ppm
Sulphate contents: max 100 ppm
The water must be treated by suitable means if it does not fulfill these requirements, i.e. by adding softened, or distilled or deionized water. Excessive sulphate or chloride contents can also be reduced by adding distilled or deionized water.

Antifreeze Coolant Liquid Manufacturer, Exporter and supplier in Mumbai, Chennai, Kolkata, Visakhapatnam, Gandhidham, Fujairah, Abudhabi, Dubai, Sharjah, UAE Middle East Gulf, Muscat Barka Sohar Oman, Kenya Nairobi Uganda Africa, Canada, Sudan, Yemen

Helps to avoid engine extreme temperatures. RXSOL ANTIFREEZE contains special anti-freeze and anti-rust additives.

 

An antifreeze is an additive which lowers the freezing point of a water-based liquid

 

Chemical stable Low Viscosity

Longer Life, Less corrosive to the metal parts & less changes

Highly effective in heat transfer

Low Freezing point & High Boiling point

Keep the engine cool & prevent the over heating

Improve the air conditioner output.

Less Scale formation & degrading

Enhance fuel performance.

Antifreeze for Extra Cold / Winter Climate

AC2 DESCALEX Powder

RXSOL AC-2 effectively not only cleans scale but also protect from rust. RXSOL AC-2 chemical is specialized detergent based acid with corrosion inhibitor for evaporators, boilers, heat exchangers, tanks, pipes, and other heat transfer equipment which are commonly fouled by scales, corrosion and other impurities.

 

RXSOL AC-2 effectively remove scale, rust and lime deposits from metal surface.

Alias: 

AC-2 INHIBITED POWDERED ACID, AC2 Inhibited Descaler, Powdered Acid Descaling Chemical, Superkleen AC2

Active Matter: 
93-98
Application: 

Powder scale remover designed for use in the chemical cleaning of evaporators, boilers, cooling towers, heat exchangers, tanks and pipes, which are commonly fouled by hard water scales, grease, tarts and other impurities.

RXSOL DESCALE contains corrosion inhibitor which provides corrosion protection even after the cleaning, unlike other acid cleaning chemicals which may increase corrosion rate after cleaning. Moreover, it contains pH indicator which facilitate monitoring of cleaning progress.

 

Packing Size: 
25.00 Kg.PWD
Using Procedure: 

Directions for Use and Dose Rates
The most effective descaling is accomplished by circulation. In the case of small components, the soak method in an immersion bath can be used. If the equipment to be cleaned is contaminated by oil, grease and sludge, then pre-cleaning with RXSOL NEW org Plus or Enviro Degreaser. Depending on the extent of scaling, use a solution of 2.5-10% Descale Powder. The solution will have a red colour which disappear when the solution is neutralised. Whenever possible, the solution should be heated to 60°C. Neutralised solutions can be reactivated by adding more Descale Powder until the red colour reappears. This should not be done more than twice. Descale Powder should not be used on aluminium, zinc, tin or galvanised surfaces. Descaling of Boilers, Descaling of Diesel Engine Cooling Water Systems, Condensers,

Evaporators, Calorifiers, Heat Exchangers:
The strength of the acid can be enhanced by adding 1 part sodium chloride (common salt) to 20 parts of Descale Powder. This enhancement of the cleaning solution, however, should not be used when descaling diesel engine cooling water systems. After use of Descale Powder a 0.5% solution of Alkalinity Control in fresh water should be used for neutralisation.

Note: 

Descale powder blended with corrosion inhibitor along with scale removing acidic powder for cleaning of rust and water scale deposits from water system. Presence of Inhibitor resulting to stop direct acidic effect on metal surface.
 

Descale  powder scale remover and cleaner formulated to remove rust and scale deposits from boilers, diesel engine cooling water systems, condensers, evaporators, calorifiers and heat exchangers.

RXSOL Descale contains corrosion inhibitor which provides corrosion protection.

This product is compatible and suitable with aluminium, copper, zinc, galvanized metals, steel boilers etc. Powder Acid for Removal of Scale and Rust

Short Description: 
RXSOL AC-2 chemical is specialized detergent based acid with corrosion inhibitor for evaporators, boilers, heat exchangers, tanks, pipes, and other heat transfer equipment

Dry acid descaling cleaner suitable for Boilers, Diesel Engine Cooling Water Systems, Condensers, Evaporators, Calorifiers, Heat Exchangers etc.

Features, Benefits and Applications
• Dry acid cleaner contains inhibitors to protect metals.
• Contains colour indicator to show the strength of the solution and anti-foam agent.
• Safe and easy handling and storage.
• Fast and effective scale remover.
• Removes scale from boilers.
• Removes scale from diesel engine cooling water systems.
• Removes scale and rust from condensers, evaporators, heat exchangers etc.
                                    

                                   **Read the Material Safety Data Sheet before using this product**

Depending on the nature of the scale and mass volume of contamination,  use descale powder with fresh water with a concentration value of 2 - 20 %.  It means for light descaling 2 Kg Descale powder can be dissolved in 100 Ltrs of water and if hard and thick deposition observed powder ratio can be increased up to 15 - 20 Kg in running cleaning solution.
 

RXSOLAC2 Inhibited Acid Descaler Powder : Powdered inhibited acid chemical specially formulated for de-scaling & de-rusting application.

 

RXSOL AC2 DESCALEX–  Easy and Safe to handle

Descale Powder is used for descaling of ships' boilers and marine diesel engine cooling water systems. Also, refer this link to equivalent suitable product http://rxmarine.com/descaling-liquid-20-ltr

Decale Powder Powder manufacturer and supplier in Muscat - Barka, Oman, Fujairah, Abudhabi, Ajman, Sharjah, Dubai, Diera, UAE Middle East, Mumbai, Kandla Gandhidham, GIDC SURAT, Navi mumbai MIDC, Taloja, Panvel, Nerul, Koparkhairna, Turbha Mahape, Rabale, Airoli, Kolkata, Howrah, West Bengal, Bihar Patna, Dehri On Sone, Jharkhand, Ranchi, Tata, Dhanbad, Varanshi, Uttar Pradesh UP, Visakhapatnam, Andhrapradesh, Manglore, Goa, Nairobi Kenya Africa, Sudan, Yemen

 

RXSOL Decale Powder improves heat transfer efficiency in heat exchangers and improve flow in pipes.
RXSOL Decale Powder effectively dissolves calcium and magnesium scale, hard water scale and variety of deposits.

Suggestion ::: Our daily descaling works helps to share helpful tricks to dissolve hard scale easily, Always use 5-10 %  our new generation hard scale deposit remover powder RXSOL-11-1102-025 . Addition of RXSOL-11-1102-025 helps to clean 100% scale from system .
 

RXSOL AC2 DESCALEX Powder is classifed in Decaling Chemicals

 

RXSOL AC2 DESCALEX Powder MOST COMMONLY used for evaporators, boilers, cooling towers, coils, plumbing system, heat exchangers and pipes.

 

RXSOL AC2 DESCALEX Powder dissolves water scales cleans microorganisms deposits and other impurities. 

 

RXSOL AC2 DESCALEX Powder developed by additon of such ingredients which effectively chemically penetrate to loose scales deposit Also RXSOL AC2 DESCALEX Powder contains corrosion inhibitor to protect from RUST. RXSOL AC2 DESCALEX Powder provides corrosion protection even after the cleaning

 

RXSOL AC2 DESCALEX Powder hleps to keep system scale and deposits free which improves heat transfer efficiency in heat exchangers and improve flow in pipes.

 

RXSOL AC2 DESCALEX Powder chemically reacts with calcium and magnesium scale to dissolves hard water scale deposits.

 

RXSOL AC2 DESCALEX Powder Super contains pH indicator which facilitate monitoring of cleaning progress.

Corrosion Protection Scale cleaning Detergent

Sodium Dodecyl Sulfate Powder

Sodium lauryl sulfate (SLS) is an anionic surface active agent commonly used in cosmetics. It is well-known for causing skin discomfort, which can lead to altered skin barrier function and water-loss. For this reason, the FDA recommends using less than 1% in personal care products. However, when used appropriately, sodium lauryl sulfate can also provide certain skin benefitting properties.

Alias: 

Lauryl Sulfate Sodium Salt, Sodium Dodecyl Sulphate, 151-21-3, Sodium Lauryl Sulfate, Dodecyl sodium sulfate, Dodecyl sulfate sodium salt SDS, Sodium Dodecyl Sulfate, SLS powder 25 Kg, Sodium dodecylsulfate, Sodium lauryl sulphate, Dodecylsulfuric A

Active Matter: 
98 - 99%
Application: 

It is used as foaming agent in tooth pastes, Shaving Creams, Powder shampoo etc. In pharmaceutical industry it is used for Tableting. It is widely used in Toothpaste, to produce Shampoo & Fire Fighting Foams. • It is used in firefighting equipment also.

Packing Size: 
25.00 Kg.PWD
Using Procedure: 

In cosmetics, sodium lauryl sulfate is most often used as an emulsifier or surfactant. As an emulsifier, sodium lauryl sulfate helps to stabilize and thicken solutions with ingredients of differing solubility. This allows products to achieve a more uniform texture for easier, and smoother application. Furthermore, the effect of sodium lauryl sulfate on surface tension is applicable to not only product formulations but also skin composition. It possesses great capacity for altering the surface tension of the stratum corneum. Consequently, topical application of sodium lauryl sulfate solutions can make the skin more permeable, thus allowing for better absorption of skin-enhancing molecules with less than ideal polarity and size. Additional applications of sodium lauryl sulfate include functioning as an effective cleansing agent (e.g. soaps and body wash)

Note: 

Handling :

Handle in accordance with good hygiene and safety procedures. Wear chemical safety goggles, rubber boots and heavy rubber gloves. Do not breathe dust, and avoid contact with eyes, skin and clothing. Avoid prolonged or repeated exposure and wash thoroughly after handling.

Storage :

Keep container tightly sealed. < + 30 °C. Store in a cool, dry, well-ventilated area away from incompatible substances.

Short Description: 
Sodium lauryl sulfate (SLS) is an anionic surface active agent commonly used in cosmetics.

Synonym : Sodium dodecyl sulfate, 151-21-3, SODIUM LAURYL SULFATE, Sodium dodecylsulfate, Sodium lauryl sulphate, Dodecylsulfuric Acid Sodium Salt, Laurylsulfuric Acid Sodium Salt, SDS

Sodium Dodecyl Sulfate Powder manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai, Sharjah, UAE, Gulf, Middle East, Muscat Oman, Kenya Africa. Get the best quality of Sodium Dodecyl Sulfate Powder at a competitive price from us. We have ready stock of Sodium Dodecyl Sulfate Powder in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

SDS Powder

Sodium Dodecyl Sulphate

Sodium Dodecyl Sulfate is an Anionic detergent and surfactant found in many personal care products soaps, shampoos, toothpaste etc.. Very effective foaming agent. We are Manufacturing in INDIA and  exporting to global market, Our name is also known as best UAE supplier of sodium dodecyl sulfate in all Middle East country.

Alias: 

Sodium Dodecyl Sulphate, Sodium Lauryl Sulphate Liquid, Also known as sodium dodecyl sulfate or SDS 50 Kg Liquid Pack
Lauryl Sulfate Sodium Salt, Sodium Dodecyl Sulphate, 151-21-3, Sodium Lauryl Sulfate, Dodecyl sodium sulfate, Dodecyl

Application: 

Application:
1. Compounded with LABSA in a proportion of 1:3, it is used as the detergent for heavy dirty to wash carpet, dishware and hard surface.
2. Widely used in shampoo, bubble bath, hand washing, and the lather agent of toothpaste, cream or powder shampoo.
3. In the other industries fields, it can be used as emulsifier, fire retardant, auxiliary agent of textile, and plating additive, etc.

 

Sodium Dodecyl Sulfate (SLS) 95%

Appearance,25℃: White to yellowish powder or needle
Odor: Characteristic odor
Active matter, %: 95.0 min.
Petroleum ether soluble substance, %: 1.5 max.
Sodium sulfate, %: 3.0 max.
Ph value (25℃, 1% Am.aq.sol): 7.5-9.5
Color, Hazen (5% Am.aq.sol): 10 max.
Water content, %: 3.0 max.

Sodium Dodecyl Sulfate (SDS ) 92%
Appearance,25℃: White to yellowish powder or needle
Odor: Characteristic odor
Active matter, %: 92.0 min.
Petroleum ether soluble substance, %: 1.5 max.
Sodium sulfate, %: 5.0 max.
Ph value (25℃, 1% Am.aq.sol): 7.5-9.5
Color, Hazen (5% Am.aq.sol): 10 max.
Water content, %: 5.0 max.

Sodium Dodecyl Sulfate (SDS ) 30%
Appearance,25℃: White to yellowish powder or needle
Odor: Characteristic odor
Active matter, %: 30±1
Petroleum ether soluble substance, %: 1.5 max.
Sodium sulfate, %: 1.0 max.
Ph value (25℃, 1% Am.aq.sol): 7.5-9.5
Color, Hazen (5% Am.aq.sol): 10 max.
Water content, %: nill
Packing

Item

Packing

QuantityFCL

N.W/FCL

G.W/FCL

SLS 95 or 92%

20kgs/Bag

525 Bags

10.50MT

10.763MT

20kgs/Bag

400 Bags

8.00MT

8.200MT

SLS 30%

200Kgs/Plastic Drum

80 Drums

16.00MT

16.800MT

1000Kgs/IBC

18 IBCs

18.00MT

19.152MT

 

SLS 95% or 92%:
1) 20kg/bag, 10.5mt/fcl (N.W.),10.763mt/fcl (G.W.) without pallet
2) 20kg/bag, 8mt/fcl (N.W.),8.2mt/fcl (G.W.) with pallet SLS 30%:
1) 200kg/plastic drum, 16mt/fcl (N.W.), 16.8mt/fcl (G.W.)
2) 1000kg/IBC, 18mt/fcl (N.W.), 19.152mt/fcl (G.W.)

Storage: Stored in dry, cool and ventilated place, kept away from sunshine and rain.

Packing Size: 
50.00 Kg.Liq
Note: 

Sodium Dodecyl Sulfate 
Sulfuric acid monododecyl ester sodium salt.

Sodium monododecyl sulfate

Sodium Dodecyl Sulfate is a mixture of sodium alkyl sulfates consisting chiefly of sodium dodecyl sulfate [CH3(CH2)10CH2OSO3Na]. The combined content of sodium chloride and sodium sulfate is not more than 8.0 percent. It contains not less than 85.0% of sodium alkyl sulfates calculated as C12H25NaO4S.

Identification—
A: Place 2.5 g in a silica or platinum crucible, and add 2 mL of 10 N sulfuric acid. Heat on a water bath, then cautiously raise the temperature progressively over an open flame. Ignite, preferably in a muffle furnace, at 600 ± 25 . Continue heating until all black particles have disappeared. Cool, add a few drops of 2 N sulfuric acid, and heat and ignite as above. Add a few drops of 2 M ammonium carbonate, evaporate to dryness, and ignite as above. Cool, dissolve the residue in 50 mL of water, and mix.

To a 2 mL portion of this solution, add 4 mL of Potassium pyroantimonate solution. If necessary, rub the inside of the test tube with a glass rod. A white, crystalline precipitate is formed.

B: Prepare a solution (1 in 10) after acidification with hydrochloric acid and boiling for 20 minutes. No precipitate is formed. Add barium chloride solution; a white precipitate is produced.

C: Dissolve 0.1 g in 10 mL of water and shake. A copious foam is formed.

D: To 0.1 mL of the solution prepared for identification C, add 0.1 mL of a 1 g/L solution of methylene blue and 2 mL of dilute sulfuric acid. Add 2 mL of methylene chloride and shake. An intense blue color develops in the methylene chloride layer.

Alkalinity—Dissolve 1.0 g in 100 mL of water, add phenol red solution, and titrate with 0.10 N hydrochloric acid: not more than 0.5 mL is required for neutralisation.

Sodium chloride—Dissolve about 5 g, accurately weighed, in about 50 mL of water.

Neutralize the solution with dilute nitric acid, if necessary, add exactly 5.0 mL of 0.1 N Sodium Chloride and titrate with 0.1 N Silver Nitrate (indicator: 2 drops of fluorescein sodium solution) to the first appearance of turbidity. Perform a blank determination, and make any necessary correction. Each mL of 0.1 N Silver Nitrate = 5.844 mg of NaCl.

Sodium sulcate— Procedure—Transfer about 1 g of Sodium Dodecyl Sulfate, accurately weighed, in 10 mL of water, add 100 mL of alcohol and heat at a temperature just below the boiling point for 2 hours. Filter through a glass filter while hot, and wash with 100 mL of boiling alcohol. Dissolve the precipitate by washing with 150 mL of water, collecting the washings in a beaker. Add 10 mL of dilute hydrochloric acid, heat to boiling, add 25 mL of barium chloride solution and allow to stand overnight. Collect the precipitate and wash with water until the last washing shows no opalescence with 0.1 N Silver Nitrate. Dry the precipitate, ignite to constant mass between 500 and 600 degrees by raising the temperature gradually, and weigh as barium sulfate (BaSO4: 233.39)

Amount (mg) of sodium sulfate (Na2SO4) = amount (mg) of barium sulfate (BaSO4) times 0.6086

Unsulfated alcohols—Dissolve about 10 g, accurately weighed, in 100 mL of water, and add 100 mL of alcohol. Transfer the solution to a separator, and extract with three 50-mL portions of Petroleum Ether. If an emulsion forms, sodium chloride may be added to promote separation of the two layers. Wash the combined Petroleum Ether extracts with three 50-mL portions of water, and dry with anhydrous sodium sulfate. Filter the Petroleum Ether extract into a tared beaker, evaporate on a water bath and dry the residue at 105o for 30 minutes, cool, and weigh. The weight of the residue is not more than 4.0% of the weight of the Sodium Dodecyl Sulfate taken.

Assay—Dissolve 1.5 g of Sodium Dodecyl Sulfate in water, warming if necessary, and dilute to exactly 1000.0 ml with water. To 10.0 ml of the solution add 25 mL Methylene blue solution (0.003 % w/v), 15 ml of methylene chloride and 20 mL of water. Titrate with 0.004 M benzethonium chloride, shaking vigorously and allowing the layers to separate before each addition, until almost the same blue color of the two layers is obtained.

1 ml of 0.004 M benzethonium chloride is equivalent to 1.154 mg of sodium alkyl sulphates, calculated as C12H25NaO4S.

REAGENTS: Potassium pyroantimonate solution—To 2 g of potassium pyroantimonate add 100 mL of water. Boil the solution for about 5 minutes, cool quickly, and add 10 mL of a solution of potassium hydroxide (3 in 20). Allow to stand for 24 hours, and filter.

Barium Chloride solution—Dissolve 12 g of barium chloride in water to make 100 mL.

Dilute Sulfuric Acid—Cautiously add 57 mL of sulfuric acid to about 100 mL of water, cool to room temperature, and dilute with water to 1000 mL.

Phenol Red solution (Phenolsulfonphthalein TS)—Dissolve 100 mg of phenolsulfonphthalein in 100 mL of alcohol, and filter if necessary.

Dilute Nitric Acid (10 percent HNO3) —Dilute 105 mL of nitric acid with water to 1000 mL.

Dilute Hydrochloric Acid (10 percent) —Prepare by mixing 226 mL of hydrochloric acid with sufficient water to make 1000 mL.

Fluorescein sodium solution—Dissolve 0.2 g of fluorescein sodium in water to make 100 mL 

Methylene blue solution—Dissolve 0.003g of methylene blue, 5.0g of anhydrous sodium sulfate and 1.2g of sulfuric acid in 100 mL of water. Anhydrous sodium sulfate is the emulsion breaker. 

Short Description: 
Excellent decontamination, emulsification, and foaming property. With rich and longstanding foam.

RX Marine International is thhe largest supplier of Sodium Dodecyl Sulphate in the whole of Indian & Middle Eastern Terrain.

We have a ready stock of SLS at Kandala, Mumbai, Ennore, Vishakhapatnam, Haldia, Fujairah and Oman

SDS Lquid

stock-clearance.png