Boiler Chemicals-42

Povidone iodine

Packing Size: 
25.00 Kg
Short Description: 
Povidone iodine

Condenser Coil Cleaner

Packing Size: 
5.00 Ltr.
Short Description: 
It is a specially engineered condenser coil cleaner and brightener. this product is recommended for use in hotels, commercial complexes, hospitals, shipyards and any air-conditioning workshops or establishments that services air conditioning systems.

Diethyl Hydroxyl Amine N,N- DEHA

Packing Size: 
0.00 Box
Short Description: 
A colourless to pale yellow transparent liquid, available as 98% DEHA and also as 85% solution in water.

DEHA

Hydrazine Hydrate

No oxygen is entering the boiler with the feed water when hydrazine is present in the water ( This will help to decrease oxygen on HP, LP boiler )

Application: 

Hydrazine is used as an oxygen scavenger for high pressure boilers in power plants and other industries to reduce corrosion of metal pipes and fittings. The test for hydrazine can be controlled by http://rxmarine.com/hydrazine-test-kit in which several solutions have been formulated into a single, stable reagent. The method is both sensitive and easy to perform. It is used mostly for the determination of small amounts of hydrazine in boiler feedwater. There are no common interferences.

The establishment of protective metal oxide layers through the use of reducing agents (such as hydrazine, hydroquinone, and other oxygen scavengers) is known as metal passivation or metal conditioning. Although "metal passivation" refers to the direct reaction of the compound with the metal oxide and "metal conditioning" more broadly refers to the promotion of a protective surface, the two terms are frequently used interchangeably.

The reaction of hydrazine and hydroquinone, which leads to the passivation of iron-based metals, proceeds according to the following reactions:

N2H4 6Fe2O3 ® 4Fe3O4 2H2O  N2
hydrazine    hematite    magnetite    water    nitrogen

 

C6H4(OH)2 + 3Fe2O3 ® 2Fe3O4 + C6H4O2 + H2O
hydroquinone   hematite   magnetite   benzoquinone   water

 

Similar reactions occur with copper-based metals:

N2H4 + 4CuO ® 2Cu2O + 2H2O + N2
hydrazine   cupric oxide   cuprous oxide   water   nitrogen

 

C6H6O2 + 2CuO ® Cu2O + C6H4O2 + H2O
hydroquinone   cupric oxide   cuprous oxide   benzoquinone   water

 

Magnetite and cuprous oxide form protective films on the metal surface. Because these oxides are formed under reducing conditions, removal of the dissolved oxygen from boiler feedwater and condensate promotes their formation. The effective application of oxygen scavengers indirectly leads to passivated metal surfaces and less metal oxide transport to the boiler whether or not the scavenger reacts directly with the metal surface.

A significant reduction in feedwater oxygen and metal oxides can occur with proper application of oxygen scavengers.

Packing Size: 
30.00 Kg
Using Procedure: 

The establishment of protective metal oxide lay-ers through the use of reducing agents (such as hydrazine, hydroquinone, and other oxygen scavengers) is known as metal passivation or metal conditioning. Although "metal passivation" refers to the direct reaction of the compound with the metal oxide and "metal conditioning" more broadly refers to the promotion of a protective surface, the two terms are frequently used interchangeably.

The reaction of hydrazine and hydroquinone, which leads to the passivation of iron-based metals, proceeds according to the following reactions:

N2H4 6Fe2O3 ® 4Fe3O4 2H2O  N2
hydrazine    hematite    magnetite    water    nitrogen

 

C6H4(OH)2 + 3Fe2O3 ® 2Fe3O4 + C6H4O2 + H2O
hydroquinone   hematite   magnetite   benzoquinone   water

 

Similar reactions occur with copper-based metals:

N2H4 + 4CuO ® 2Cu2O + 2H2O + N2
hydrazine   cupric oxide   cuprous oxide   water   nitrogen

 

C6H6O2 + 2CuO ® Cu2O + C6H4O2 + H2O
hydroquinone   cupric oxide   cuprous oxide   benzoquinone   water

 

Magnetite and cuprous oxide form protective films on the metal surface. Because these oxides are formed under reducing conditions, removal of the dissolved oxygen from boiler feedwater and condensate promotes their formation. The effective application of oxygen scavengers indirectly leads to passivated metal surfaces and less metal oxide transport to the boiler whether or not the scavenger reacts directly with the metal surface.

A significant reduction in feedwater oxygen and metal oxides can occur with proper application of oxygen scavengers.

Note: 

Why control balance of Hydrazine must required ?
Control of Hydarazine level in Boiler water is very important.  As proper level maintenance protect metal machinery parts from corrosion, However, precautions must be taken to prevent excess dose of hydrazine chemical as excess hydrazine will begin to decompose at temperature above 200oC to form Ammonia.

Hydrazine is one of popular an alternative Oxygen Scavenger. It is very important to protect boiler components from feed boiler water corrosion. 

Test Procedure ::: rxmarine.com/hydrazine-test-kit

Short Description: 
No oxygen is entering the boiler with the feed water when hydrazine is present in the water ( This will help to decrease oxygen on HP, LP boiler )

Hydazine Dose Level

Thumb rule for Hydarzine dose is, Low pressure boiler required high dose of Hydrazine ( 0.1 to 0.2 ppm level of hydrazine ) While for High pressure boiler low dose of hydrazine required (0.05 to 0.1ppm value)

 

Recommended dose of Hydrazine :

Low Pressure Boiler ( 0 to 40 bar )

0.10 to 0.2  ppm level  

Medium Pressure Boiler ( 41 to 60 bar )

 0.1 to 0.15 ppm level  

High Pressure Boiler ( more then 60 bar) 

0.05 to 0.10 ppm level

 

Valuable Boiler Water Treatment Chemicals :

Hydrazine Hydrate (50 ~ 51% as N2H4) plays very important role for corrosion protection in boilers.

Activated Hydrazine (34 ~ 35% as N2H4) Catalyzed Hydrazine solution for corrosion Protection and related equipment.

Morpholine (C4H9NO). Technical Grade for Boiler Water Treatment. Purity Not less than 99%.

Acid Inhibitor : For the suppression of Hydrochloric Acid attack on Ferrous alloys, Cuprous alloys and Titanium alloys, effec up to 94°C with efficiency not less than 75% in 5% HCI solution and Acid Inhibitor concentration 2%.

Ammonia 25% (NH4OH).
25% as ammonium Hydroxide used high pressure Boiler water treatment.
It is a clear colorless liquid.
PH 11-12 @ 20 °C.
Density 0.9 g/cm3.
Chloride (CL) 0.002 mg/liter maximum.
Iron (Fe) 0.002 mg/liter maximum.

Hardness Stabilizer :
Polyacrylate material of low molecular weight.
Non-volatile used for scale inhibition in sea water treatment.
The product is miscible with water in all proportions. And is clear Liquid.
PH valve 5-7.
Density @ 20°C Approx. 40%.
Chemical Characterization Sodium Polyacrylate, Modified, Aqueous solution.
Solidification temperature -20°C.
Flash point >100°C.
Ignition temperature >200°C.

Hydrazine Hydrate supplier in Mumbai, Kolkata, Gandhidham, Chennai, Visakhapatnam, Fujairah, Dubai, Sharjah. Hydrazine Hydrate plays very important role for corrosion protection in boilers water treatment.

No oxygen is entering the boiler with the feed water when hydrazine is present in the water ( This will help to decrease oxygen on HP, LP boiler ) Hydrazine Hydrates. Hydrazine derivatives also used in the manufacture of herbicides and fungicides, as well as plant growth regulators.

#HYDRAZINEhydrate_SharjahAbudhabi
#hydrazineHYDRATE_RuwiBARKA

Zinc Chloride Solution

Packing Size: 
45.00 Kg
Short Description: 
Zinc chloride solution is a colorless liquid. It is mildly corrosive to metals. It causes burns to eyes skin and mucous membranes.

EDTA Solution 0.1 M , 500 ml

Packing Size: 
1.00 Bottle
Short Description: 
EDTA

Hydrogen Peroxide Food Grade 35%

Hydrogen peroxide is a chemical compound with the formula H2O2. It is the simplest peroxide (a compound with an oxygen-oxygen single bond) and in its pure form is a colorless liquid, slightly more viscous than water.

Alias: 

Hydrogen Peroxide food Grade 35%

Application: 

Hydrogen Peroxide has many use including House Hold, Domestic. Agriculture, Textile, Industries, Medical and West water Treatment.

Packing Size: 
30.00 Ltr.
Using Procedure: 

House Hold : One of the most common uses of hydrogen peroxide is as a disinfectant. Spray it on surfaces like kitchen counter top and wipe with a clean rag. It can be used as a mouthwash too. You have to dilute the chemical with water and use it for rinsing the mouth. This mouthwash is also said to whiten teeth. Ensure that you do not swallow the liquid, while rinsing.
It can also be used to wash vegetables and fruits, in order to get rid of germs and pesticides. Add some hydrogen peroxide to a bowl full of water (you may also add a few pinches of salt). Soak the veggies and fruits for some time. Remove them and rinse with cold water, before use.This chemical is also used to purify water in swimming pools.
 

Agriculture : Farmers use it as an insecticide. They spray diluted form of this chemical, on plants, so that the pests and weeds get killed, without causing harm to the plants. Its also used for watering plants. Mix an ounce of this chemical with a quart of water and use it on plants. Apart from boosting the level of oxygen in the soil, this mixture is also said to prevent root rot. Some people soak seeds in it, after diluting it with water. It is said that this will fasten the process of germination. For this purpose have to mix 1.5 teaspoons of hydrogen peroxide in a cup of water.

Textile: It acts as a stain remover. Put 1 spoon tea in 1 bucket water  and let it sit for a while. After that, rinse the stains with water and soap.
As it has bleaching property, it is used as a bleach too.

IIndustrial :

Reduced Sulfur Compound Treatment for Refinery Wastewater

Sulfur compounds, such as hydrogen sulfide, thiosulfates and mercaptans, can present serious refinery wastewater problems. Hydrogen peroxide treatment is a cost effective way to treat these reduced sulfur species.

Supplemental Dissolved Oxygen to Reduce BOD and COD

Hydrogen peroxide has been used to reduce BOD and COD in refinery wastewater Supply of Supplemental Dissolved Oxygen (DO) when biological treatment systems experience temporary overloads or equipment failure.Predigestion of wastewater which contains moderate to high levels of compounds that are toxic, inhibitory or recalcitrant to biological treatment.As indicated by these examples, hydrogen peroxide can be used as a stand-alone treatment or as an enhancement to existing physical or biological treatment processes, depending on the situation.

Wastewater Pretreatment
Hydrogen peroxide is one of the most versatile, dependable and environmentally compatible oxidizing agents. The relative safety and simplicity of its use as an oxidizing agent has led to the development of a number of applications in refinery wastewater systems.

 

Note: 

Product specification

Molar mass :::--- 34.0147 g/mol
Appearance :::--- light blue; colorless in solution
Odor :::--- sharpBoiling point :::--- 150.2 °C, 423 K, 302 °F
Solubility in water :::---Miscible
Solubility :::--- soluble in ether, alcohol insoluble in petroleum ether
Viscosity :::---1.245 cP (20 °C)

Short Description: 
Pure food grade form is a colorless liquid, slightly more viscous than water.

Hydrogen Perxoide supplier and exporter in India and Middle East. H2O2 used as an oxidizer, bleaching agent and antiseptic.

#HydrogenPEROXIDE_Oman
#HydrogenPEROXIDE_Sharjah
#HydrogenPEROXIDE_NaviMUMBAI
#HydrogenPEROXIDE_Gandhidham
#HydrogenPEROXIDE_ParadipVIZAG

Hydrogen Peroxide 35% Exporter Importer and supplier in India UAE Oman, Nairobi, Canada. Pure Hydrogen Peroxide supplier in RUWI BARKA, Muscat Soha Oman, Fujairah, Sharjah, Ajman, Abudhbai, Dubai, Mumbai, Surat GIDC, Gandhidham, Chennai, Kolkata, Visakhapatnam, AndhraPradesh, Ennore, Paradip

H2O2 Food Grade

Alkalinity Reducer

RXSOL-50-5005-025  Concentrated liquid neutralising agent for corrosion control in condensate and feed water systems, contain blends of low, medium and high volatility amines that provide great protection and neutralization of acidic gases, such as CO2 throughout a condensate system. Protects boiler surfaces by forming an iron tannate film.
A liquid neutralizing amine used to control corrosion and pH in steam and condensate systems.

Alias: 

Maxtreat 3005, pH CONTROLLER AMINE base Amerzine 25 Ltr

Active Matter: 
88 - 93 %
Application: 

RXSOL-50-5005-025 is a blend of volatile liquid / steam distributions ratios that neutralise the acid contaminants in condensate and feed water thus providing protection against acid corrosion in the complete system.The most common cause of acid corrosion in condensate and feed water systems is dissolved carbon dioxide. Condensate control neutralises this acid and maintains the condensate and feed water in an alkaline condition
Used in medium and high-pressure boilers including ultra high-pressure boilers.

Fields Of Application:-
RXSOL-50-5005-025 is an effective neutralizing type corrosion inhibitor & oxygen scavanger  for steam condensation system. And can also be used to protect Boilers /Metals surfaces form corrosion.It removes oxygen efficiently in open feed systems and gives effective corrosion inhibition of boiler/exhaust gas economizer system surfaces . Its Chemical reaction by converting Fe2O3 (rust) to organic iron compound protect further IRON rust reaction .

Operating Process:-
RXSOL-CC72 neutralizes the acid components of feed water.The proportion of RXSOL-50-5005-025 depends upon the Carbon dioxide content of the condensate. Basically RXSOL-50-5005-025 neutralizes the acid contents & maintains the condensate and feed water in the alkaline condition.  It also protects copper based metals.

PRODUCT APPLICATION

Used as solvent, as an intermediate in making of dyes, pharmaceuticals, fragrances and as an insect pheromones.

Packing Size: 
210.00 Ltr.
Using Procedure: 

RXSOL-50-5005-025 condensate is tested for PH to determine the dosage level. The PH limits are 8.3 - 9.0 . For an average system e. g. 10-M3, the dosage is approximately 0.65 ltr / day .

The necessary amount of RXSOL-50-5005-025 is required or injected as frequently as to maintain the pH of the condensate at the main condensate pump outlet between 8.6-9.5 .  The amines pass over with the steam and have the dual function of elevating the pH of the steam/condensate and putting a protective micro film on the system pipe work. Acidic condensate is the result of carbonic acid (H2CO3) being formed as CO2 is released in the steam.Condensate prevents corrosion by carbonic acid on live systems. Its filming properties also reduce corrosion on shut down lines, when moisture and oxygen are present.

Note: 
  • Easy to use liquid treatment.
  • Neutralizes the acids occurring in the condensate system.
  • Less maintenance required. Lower operating costs and increased reliability.
  • Volatilizes and carries over with the steam and so is recycled. Dosage is economical and efficient.
  • Simple test to determine level of treatment.
  • Used for protection of condensate and feed water systems in boiler systems of all pressures.

PRODUCT INTRODUCTION

Pure anisole or methoxybenzene, is an organic compound. CAS NO: 100-66-3

HANDLING & STORAGE

Keep away from heat and sources of ignition.

Store in a sealed condition at ambient temperature or below. Keep containers in tightly closed condition.

Use proper PPE during handling.

PRODUCT APPLICATION

Used as solvent, as an intermediate in making of dyes, pharmaceuticals, fragrances and as an insect pheromones.

PROPERTIES

Appearance

Clear Colorless Liquid

Purity ( by GC ) , %

99.8 Min

Specific Gravity @25°C

0.9995 ± 0.05

Moisture (by KF) , %

0.3 Max

 

PACKAGING

Packed in drums or in ISO TANKS on request.

Short Description: 
Alkalinity controller-Reducer to Maintains pH in Boiler Water. Concentrated liquid neutralising agent for corrosion control in condensate and feed water systems, contain blends of low, medium and high volatility amines that provide great protection and neutralization of acidic gases, such as CO2

Why Condesate control ( Condensnol Amine ) required as BOILER Water Treatment chemicals?

Condensate control plays very important role to neutralize Acidic nature of boiler water steam during condensation process. As acidic nature rapidly corroding metal body of BOILER and surrounding system.

What is the main base and chemical principle of Condensate Control (Condensnol Amine )?

Condensate control contain mixture of condensnol amine which helps to neutralize acidic media which causes corrosion in boiler system. On the other hand we can say that condensate control works as a corrosion controler in steam and condensate systems.

Is Condensate System can be kept safe by using Condensnol amine - condensate Control?
 

Condesnol Amine ihighly effective product to CONTROL acidic strength of CONDENSATE SYSTEM. During liquid treatment Condensnol amine neutralises the acids in the condensate system.

Is Condensate control is easy to use?

RXSOL-50-5005-025 condensate is tested for PH to determine the dosage level. The PH limits are 8.3 - 9.0 . For an average system e. g. 10-M3, the dosage is approximately 0.65 ltr / day .

The necessary amount of RXSOL-50-5005-025 is required or injected as frequently as to maintain the pH of the condensate at the main condensate pump outlet between 8.6-9.5 .  The amines pass over with the steam and have the dual function of elevating the pH of the steam/condensate and putting a protective micro film on the system pipe work. Acidic condensate is the result of carbonic acid (H2CO3) being formed as CO2 is released in the steam.Condensate prevents corrosion by carbonic acid on live systems. Its filming properties also reduce corrosion on shut down lines, when moisture and oxygen are present.
 

How Condensate control works?

Condensate control contains volatile amine which helps to neutralising the acidic contaminants pH of the system and keep the whole boiler and condenser system workable in good running condition for future use.

The condensate system contains high level of carbon dioxide in presence of vaporized steam the rapid formation of carbonic acid takes place which corrodes the metalic content rapidly.

 

Condensate control cuts down such formation and facilitates in maintaining favourable environment for metalic parts. The dosage of condensate control depends on the aggregate carbonic acid content and should be added till the point the pH range is 8.3 to 9.

#BoilerWATERtreatment_AlkalinityControl
#BoilerCHEMICAL_UAEdubai
#boilerWATERtreatment_MuscatOMAN

Condesate Control supply and Stock location.
We are one of largest condensate control manufacturer and supplier in Kolkata - Haldia - Paradip, Mumbai - JNPT - Pirpav - Chembur, Chennai - Ennore, Visakhapatnam - Gangavaram, Kandla, Mundra, Sikka, Salaya, NAvlakhi, Surat - Hazira, Fujairah, Dubai, Abu Dhabi, Sharjah

Protection of Condenser from Corrosion in Boiler / Power plant.

Condenser  and its related accessory like condensate pump protection from corrosion is important task to avoid high maintenance cost due to acidic cavitation which can cause plant unplanned downtime. Unnecessary condenser maintenance also effect production yield.

What is condenser?

Condenser helps to condensate high temperature steam to water which can be collected and returned to further utilize in the steam generator. During condensation condensate control works during super heated temperature steam to neutralize or prohibit acid formation which is causes of cavitation and rusting etc...

Benefit of uses of Condensate Control - Condensnol amine?

Save maintenance cost
Avoid down time of system.

Increase production yield.

Acidic medium causes rust / cavitaion which is resulting more vibration of motor plant machiner, Condensnol Amine uses effectively neutralizes Acid during condensation.

Alkalinity controller-Reducer to Maintains pH in Boiler Water

Pottasium Alum

Packing Size: 
25.00 Kg
Short Description: 
It is an inorganic salt also called potassium aluminium sulphate .

Oxygen Scavenger Boiler Oxy Control

This is most common oxygen treatment as a scavengers used to effectively remove dissolved  OXYGEN from your feedwater. By the presence of dissolved oxygen in system, corrosion and pitting caused on metal surface. Removes dissolved oxygen, By acting as an oxygen scavenger.

Alias: 

HYDREX 1802

Application: 

Oxygen Treatment scavenger is a class of chemicals added to react and remove oxygen in water to protect against oxygen induced corrosion. The use of Oxygen Scavenger Boiler Oxy Control  as a chemical deoxygenator is economical within certain limitations imposed by the dissolved oxygen content. Oxygen Scavenger Boiler Oxy Control is relied on as the sole means of oxygen removal. Generally, costs are balanced by removal of as much of the oxygen as feasible by mechanical means, e.g. deaerator and by using Oxygen Scavenger Boiler Oxy Control to react with the residual oxygen.

To prevent corrosion and pitting it is desirable to feed the Oxygen Scavenger Boiler Oxy Control. Oxygen scavengers capture the dissolved oxygen in a harmless chemical reaction that renders the oxygen unavailable for corrosive reactions. 

Packing Size: 
30.00 Kg.Liq
Using Procedure: 

Theoretically, 7.88 pounds of RXSOL-42-1524-030 are required to remove one pound of oxygen. The efficiency of the oxygen removal is estimated at 75 per cent to allow for oxidation in contact with air, blowdown losses, etc. Therefore it is estimated that 10 pounds of RXSOL-42-1524-030 are required for each pound of oxygen removed (or 10 ppm RXSOL-42-1524-030 per 1 ppm dissolved oxygen.)

Note: 

BENEFITS -

RAPID REACTION :

The catalyst RXSOL-81-6119-220 speeds up the removal of dissolved oxygen. Oxygen can be removed completely even from cold water due to catalytic action. Normal reaction time is as low as 15 to 20 seconds as against 10 to 30 minutes for uncatalysed sulphite.

EASY TO HANDLE :

RXSOL-81-6119-220 is a free flowing powder. It is soluble in water even at lower feed water temperature.It is non-toxic and non-corrosive and, therefore, can be handled easily.

pH CONTROL :

RXSOL-81-6119-220 is formulated to get proper pH control for optimum availability of catalyst for rapid oxygen removal.

COST EFFECTIVE :

The catalytic action reduces the excessive requirement of sulphite in feed water for the rapid removal of oxygen. Thus the quantity required is lower, making RXSOL-81-6119-220 treatment cost effective.

APPLICATION AND DOSAGE :

RXSOL-81-6119-220 solution should be dosed continuously. Dissolve the required quantity of RXSOL-81-6119-220 gently in boiler feed water in a separate tank. Dose this solution continuously in the boiler feed water line after the deaerator.

Above 8 ppm of sodium sulphite is required for the removal of 1 ppm of dissolved oxygen from boiler
feed water. About 10% to 20% of excess sulphite should be dosed to provide oxygen consuming reserve.

The table below gives the approximate dosage.

Feed Water Temperature RXSOL-81-6119-220 dosage in gms per ton ofsteam generation

More than 80oC

15
60 to 80oC 30
40 to 60oC 60
Less than 40oC 100

The rmax will provide technical assistance in arriving at optimum dosages for your operating conditions and requirements and in selecting a suitable dosing system for your plant

HANDLING, STORAGE AND PRECAUTIONS :

RXSOL-81-6119-220 is mildly alkaline in nature. Normal precautions should be taken while handling solid powders. In case of contact, wash with water. Do not swallow.

RXSOL-81-6119-220 should be stored in a dry condition. Close the container tightly to avoid contact with air.

PACKING :

RXSOL-81-6119-220 is available in 50 kg polythene lined bags.

Short Description: 
Dechlorination product which is frequently used in municipal wastewater, pulp & paper, power, and textile water treatment plants and as a Oxygen scavenger in Boiler water treatment. Also popular for preservative in photo developer process and Food additive.

Oxygen Scavenger Boiler Oxy Control effective OXYGEN SCAVENGER for drilling fluid.

An oxygen scavenger is a chemical substance that is used to reduce or completely remove oxygen in fluids and enclosed spaces to prevent oxygen-induced corrosion

Oxygen Scavenger Boiler Oxy Control works as an oxygen absorber. It is used as a corrosion inhibitor in oil and gas production installations, packaging, production separation and seawater injection systems. Oxygen scavengers increase the shelf life or service life of the components under protection

Oxygen scavengers are categorized as organic or inorganic. They are applied in various ways, depending on

Oxygen Scavenger Boiler Oxy Control is  soluble in water. It is noncombustible. It is corrosive to aluminum. It is a strong irritant to skin and mucous membranes. It is toxic by skin absorption.

Oxygen Scavenger Boiler Oxy Control supplier and exporter from Mumbai, Chennai, Kolkata, Visakhapatanm, Gandhidham, Fujairah, Sharjah, Dubai, Abudhabi, Gulf Middle East, Muscat Barka Sohar Oman, Nairobi Kenya Africa, Canada

We are a leading manufacturer and exporter of oil fields chemicals.

We are offering the following chemicals used in oil extracting industries as an oxygen scavenger, in water treatment to remove dissolved oxygen and in manufacturing of caramels. We are committed to provide high-quality products and service to our customers.

Please feel free to keep in touch with us about any of your business-related inquiries / requirements.

Oxygen Scavenger for Boilers

stock-clearance.png