How to use Evaporator Treatment Chemicals

 Dosage :

Daily Out Put Evaporator Daily  RXSOL VT 6001 Requirement
10  - 20 MT 100-200 ML
30 – 40 MT 300-400 ML
50 – 60 MT 500-600

Setting the Flow RateThe treatment is added to the dosage tank and mixed with water. Example: With the 0.5 litres of Vaptreat add sufficient water to make up 50 litres of liquid.The standard flow meter is Adjustable-Rate=0-l00ml/minute.Flow rate calculation: Flowrate = 50 Litres/24 x 60= 35 ml/min setting  i.eThis will last 24 hours.

Note: We can remover  existing  mineral scale deposits  by using  A  5-10%  solution of  RXSOL-51-6001-020

Email us to get factory sale price of Evaorator Treatment Chemicals - Corrosion inhibitor for  vaporizer   ::: mail@rxmarine.com