Corrosion Inhibitor for Diesel Cooling Water Treat
Product Description | Product Application | Product Notes| Product DOSE
Corrosion Inhibitor for Diesel Cooling Water Treatment - RXSOL CIDC is a unique formulation with organic Corrosion Inhibitors, Anti-Scalant for use in closed cooling water systems, for preventing corros
Corrosion Inhibitor for Diesel Cooling Water Treatment - RXSOL CIDC is a unique formulation with organic Corrosion Inhibitors, Anti-Scalant for use in closed cooling water systems, for preventing corrosion and scale Formation in Internal combustion engines, compressor cooling system, DG -set at high or low temperature. It is a concentrated liquid, also used as a corrosion inhibitor ( Protects all the metals including cast iron, mild steel, copper .)
Code: RXSOL-40-4033-025
Other Equivalent Brand E.W.T. Inhibitor 9-131c, Water-soluble corrosion inhibitors FOR MTU engine, RXSOL CIDC
Short Description: Anti-Scalant for use in closed cooling water systems , for preventing corrosion and scale Formation in Internal combustion engines, compressor cooling system, DG -set at high or low temperature. It is a concentrated liquid , also used as a corrosion inhib
Generic Name: Water-soluble corrosion inhibitors FOR engine water treatment
Information:
Water-soluble corrosion inhibitors FOR MTU engine, RXSOL CIDC specialized product for Marine and shipping industrial use. Major supplier in all INDIAN and UAE Middle East coastal. RXSOL CIDC Prolong the life of equipment by keeping scale and corrosion free.
Active Matter: 45-50
IMPA Code: 551086,
Corrosion Inhibitor for Diesel Cooling Water Treat
Application:
The stable oxide film that is formed by RXSOL CIDC prevents corrosion caused by the electrolytic action between dissimilar metals used in the system .RXSOL CIDC has been field tested and found to have n
The stable oxide film that is formed by RXSOL CIDC prevents corrosion caused by the electrolytic action between dissimilar metals used in the system .RXSOL CIDC has been field tested and found to have no detrimental effects on non-metallic substances such as seals, glands, packing, hoses, gaskets etc., normally used in these’ systems.
Application-Dg*
Sets Internal combustion engines closed circuit cooling system compressor cooling system. RXSOL CIDC incorporates superior corrosion inhibitors to prevent corrosion works by free of scale deposits.
Using Procedure:
Initial dosage for an untreated system is 9 litres of RXSOL CIDC / 1000 litres of untreated distilled water. This will bring the treatment up to the minimum level of 1000 ppm nitrite. For best result and prolo
Initial dosage for an untreated system is 9 litres of RXSOL CIDC / 1000 litres of untreated distilled water. This will bring the treatment up to the minimum level of 1000 ppm nitrite. For best result and prolonged engine life add RXSOL CIDC every 500 -6500 km. or 250 to 300 hours of running time or every 2 month interval.
Note:
In cases where systems are contaminated with oil and/or scale, they should be cleaned before starting to apply RXSOL CIDC.There are suitable RX BRAND products to carry out the cleaning. Degreasing should be carried out using RXSOL-20-2002-025 and descaling by using RXSOL 1008.
Technical Specifications:
SPECIFICATION / HANDLING
Color : Odour Pink/ red (Colour changes of the product cannot be excluded the effects will however not impaired.)
Sp. Gravity : 1.1 to 1.25
pH : Alkaline (11.3 – 11.5)
None. Rxsol-2000 is an alkaline product & should be handled like other chemical Avoid contact with Eyes, Skin, in case of contact, wash with copious amounts of water immediately.
Freezing Point - 17 0 c
Nitrite (as PPM NO2) 0 100-200 300-600 700-900 1100-1300 1440-2400
RXSOL CIDC /1000L 13.0 11.3 8-10 5-7 1.5-3.5 0
Remarks:
METHOD OF USE
1. Properly clean the system with water and alkaline liquid, if necessary.
2. Add 0 .15-1.5 % of RXSOL CIDC in the system or recommended Nitrite level 1400 – 2500 ppm can be measured and controlled by any standard RXSOL test kit for Nitrite, Chloride test also helps to detect excess contamination to maintain acceptable levels. when the product is dosed as recommended limit By buffering action of RXSOL CIDC, pH should be maintained between 8.3 and 10 by the treatment.
RXSOL CIDC Water-soluble corrosion inhibitors FOR MTU engine.
Advatages : -
1. Prolong the life of equipment by keeping scale and corrosion free. Since RXSOL CIDC is alkaline and so will suppress acid corrosion, which would otherwise result in corrosion damage such as pitting. However, the alkalinity control is such that even if the product accidentally overdoses, the pH of the water will remain within limits. The metals which would be affected by extremes of alkalinity or acidity are protected.
2. Improves generating cooling efficiency by maintaining a clean heat transfer
3. Corrosion protection by using a superior corrosion inhibitor.
4. Reduced maintenance and downtime
5. Compatible with Coolants / Antifreeze solution / Glycol .
6. Friendly with Metals (Like steel, Copper, Aluminum, all alloys) & Non-metal (Rubber, Hoses, Gasket etc.)
Marine Diesel Engine specialized corrosion inhibitor.
NOTE : Initial dosage for an untreated system is 9 litres of RXSOL CIDC / 1000 litres of untreated distilled water. This will bring the treatment up to the minimum level of 1000 ppm nitrite. For best result and prolonged engine, life add RXSOL CIDC every 500 -6500 km. or 250 to 300 hours of running time or every 2-month interval.
Marine Chemicals
Boiler water treatment chemicals
Fuel oil treatment chemicals
Tank cleaning chemicals
Test kits and reagents
Cooling water treatment chemicals
Oil spill dispersant
Electric cleaning chemicals
Air cooler cleaning chemical
Antiscalants
Defoamers /Surfactants
Oxygen Scavengers
Custom Blending of Water Treatment Chemicals
Water Treatment Chemicals - Raw
Coagulants
Flocculants
Disinfectants
Corrosion Inhibitors
RXSOL WATER TREATMENT CHEMICALS :
1. Sodium Chloride salt for softeners
2. Calcium hypochlorite 65-70%
3. Ferric Chloride 40%
4. Sodium metabisulphite powder
5. Sodium Bromide.
6. Bromine Tablets suppliers in uae, Dubai, Sharjah.
7. Sodium Nitrite.
8. Sodium Molybdate
9. Phenolphthalein White
10. Caustic Soda liquid, Prills and flakes.
11.Ferrous Sulphate.
12.Poly Aluminium Chloride (PAC).
13.Calcium Nitrate.
14.Calcium Chloride.
15.Sodium Sulphite.
16.Silica Sand and Gravel filtration media.
17.Birm and Anthracite.
18.Hydrazine Hydrate.
19.Carbohydrazide liquid and powder.
20.Cobalt Sulphate.
21.Zinc Chloride and Zinc Sulphate
22.Borax Pentahydrate and Borax Decahydrate
23.Citric acid solution and powder.
24.Sodium Hexameta phosphate.
Boiler Water Treatment Chemicals
Precleaning & Passivation
Scale Inhibitors
Corrosion Inhibitors
pH Booster (Inorganics & Organics)
Descaling Chemicals (online / offline)
Sludge Conditioner
Condensate Treatment Chemicals
Amine Based treatment Scale Inhibitors
Corrosion Inhibitors
Biocides
Biodispersant
Dealkalisers
Descalants
Cooling Water Treatment Chemicals
Chiller Water
Treatment Chemicals
Pre cleaning Chemicals
Anticorrosion Treatment
Antimicrobial Treatment
STP Treatment Chemicals
Biocultures
Deodorants
Biomass Setting Agents
Disinfectants
Defoamers
Nutrients
Enzymes
ETP Treatment Chemicals
Coagulant
Flocculant
Decolorant
Dewatering Aids /
Filter Aids
Bioculture – Anaerobic & Aerobic
Deodorants
De-Emulsifiers
Polymers for Filter Press /
dewatering Evaporator Antiscalants
Water Treatment Chemicals
Biocides
Coagulants/flocculants
Corrosion inhibitors
Defoamers
Dust control products
Membrane treatments
Metal passivators
Monitoring and control systems
Odor inhibitors
Oxygen scavengers
Scale inhibitors
Sludge dewatering polymers
MUNICIPAL water treatment chemicals
Coagulants/flocculants
Defoamers
Feed / make down equipment
Membrane treatments
Mixing equipment
Odor inhibitors
Scale inhibitors
Sludge dewatering polymers
MINING & MINERAL PROCESSING
Coagulants/flocculants
Dust control products
Filtration aids
Grinding aids
Monitoring and control systems
Non-sulfide flotation reagents
Rheology modifiers
Scale inhibitors
Specialty dewatering aids
Viscosity modifiers
CHEMICAL PROCESSING
Biocides
Cleaners
Coagulants/flocculants
Corrosion inhibitors
Defoamers
Membrane treatments
Monitoring and control systems
Odor neutralizer
Oxygen scavengers
RO Membrane Treatment Chemicals
RO Pre -Treatment Chemicals
Membrane Antiscalants
Raw water RO (Food grade)
Effluent Recycle RO
Desalination Plants
Membrane Antioxidants
Membrane Cleaning Chemicals
Membrane Preservatives
Online / Offline Biocides
pH Boosters (Food Grade)
Taste Enhancers for RO Product water
Sanitizing Products for PSF, ACF Filter
Media and Pipelines.
Sugar Process Chemicals
Boiler Treatment Chemicals
Juice Clarification Aids
Syrup Clarification Aids
Mill Sanitation Chemicals
Viscosity Reducer
Anti Foamer / Defoamer
Evaporator Antiscalant & Descalants
Sugar Refining Compounds
Color Precipitants
Paper Process Treatment Chemicals
Anti Slimicides
Defoamers
Chemicals For Krofta Applications
Boil –out Chemicals
Vacuum Pump Antiscalant
ETP Chemicals
Packing Size: 25.00 Ltr.
Available Packing Size:
5, 10, 20 / 25 / 35 / 50 / 210 Ltrs customized and private labeling option available for Water-soluble corrosion inhibitors FOR MTU engine. Mail us for MSDS and technical bulletin as well as for factory discounted sale price. Corrosion Inhibitor for Diesel Cooling Water Treatment, Ready stock at KANDLA, Mundra, Mumbai, Chennai, Vizag - Visakhapatnam, Kolkata - Haldia, Fujairah - Dubai, Middle East - UAE.
Article News:
,
HASHTAG:
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride