Alkalinity Control

SKU: RXSOL-50-5002-025

Boiler Water Treatment Chemicals Concentrated liquid alkaline product for corrosion and Calcium scale control in boilers.  Very usefull Concentrated Alkaline Liquid For Maintaining Ph - To adjust alkalinity

Suitable for Low-pressure boiler systems (0-32 bar) , medium-pressure steam propulsion vessels (32-60 bar). And also suitable to  used for high pressure steam generating systems (60-84 bar).

Mechanism :  It converts calcium hardness into soft, non-adherent sludge that is easily removed by blowdown.

Alias: 

GREEN AC, Alka active liquid, GC Concentrated Alkaline Liq, GC, Alka Treat, ACT 100 NORCHEM, Alkaline Treatment Liquid 9-512, Eazy Neutralise, ALKATREAT, Nalco 77224, PH Neutraliser, Maxtreat-3004, Nalco 77222, Chem 3004- Alkali, DREW GC, Alkanity Control 25 Ltr

Active Matter: 
58 - 63%
Application: 

RXSOL-50-5002-025 provides the alkaline condition for hardness control to function correctly. Without the correct precipitation and subsequent blow down of hardness salt, scale would form. This would result in restriction in water flow, ineffective heat transfer and local corrosion. The end effect would be an inefficient boiler and ultimately component failure. RXSOL-50-5002-025 also provides the alkaline condition required for corrosion control, by neutralization of acidic gases

Packing Size: 
25.00 Ltr.
Image: 
Using Procedure: 

For optimum results dose RXSOL-50-5002-025 direct to the boiler with a RXSOL Boiler Water Treatment Dosing unit, or via the bypass pot- feeder installed in the boiler feed line.

Required dosage can be controlled by pH & alkalinity test dosage chart .  

1 milliliter of RXSOL-50-5002-025 concentrated alkaline liquid per ton of distilled water provides 0.5 ppm of lkalinity hydrate.

Low-pressure boiler (up to 28 bars)

Add RXSOL-50-002-025 to 5 litre in feed – water, There is no any specific method can be passed through the recalculating or the main feed pipe into the stream or the hot well tank.

High – Pressure Boiler (28 to 60 bars)

Dissolve the desired volume of RXSOL-50-002-025 to 5 ltr of feed – water, which should then be passed  into the stream or water drum through the chemical pump.

 
Note:- It can also be used as a neutralizing agent following acid cleaning with  descaling materials ( RXSOL-11-1008--DC descaling Liq / RXSOL-54-1008-SA Safe Acid PWD ) 

Note: 

It can also be used as a neutralizing agent following acid cleaning with  descaling materials ( RXSOL-11-1008--DC descaling Liq / RXSOL-54-1008-SA Safe Acid PWD ) 
 

CHARACTERISTICS

  • Alkalinity Balace mechnism to control corrosion.
  • It converts calcium hardness into soft, non-adherent sludge that is easily removed by blowdown. Treated as good salt-scale controler product.
  • Compatible with other BOILER chemicals
  • Tested with long and continious running plant for more then 20 Years and easy to apply and use.
  • Avoid contact with any acidic / oily - FAT materials.
Short Description: 
Alkalinity Builder Very usefull Concentrated Alkaline Liquid For Maintaining Ph which protects corrosion, scalling by controlling Calcium scale in water system.

Testing control procedure

  1. Test water sample from the water boiler as described in the direction of the  Alkalinity Test Kit ( p & m Total ) http://www.rxmarine.com/Alkalinity-test-kit
  2. Determine the present alkalinity value expressed as ppm CaCO3 .
  3. Desired level of 100-150 ppm as CaCO3.
  4. A control test for the alkalinity  of the water should be conducted after 3- 6 hours from the application.

CHARACTERISTICS

  • Alkalinity balace mechnism to control corrosion.
  • It converts calcium hardness into soft, non-adherent sludge that is easily removed by blowdown. Treated as good salt-scale controler product.
  • Compatible with other BOILER chemicals
  • Tested with long and continious running plant for more then 20 Years and easy to apply and use.
  • Avoid contact with any acidic / oily - FAT materials.

Alkalinity Control works as PH Neutrilizer in Boiler system. Alkalinity control one of important boilere water treatment chemicals which plays very important role by controlling corrosion and solid deposits in boiler system.

Alkalinity control makes sludge in soft form, which can be easily blown down from bottom side of BOILER.

Other valuable Boiler Water Treatment Chemical product :

RXSOL-50-5020-025 Boiler Water Treatment Auto
RXSOL-40-4091-025  Scale and Corrosion Inhibitor for Cooling Water
RXSOL-40-4009-025 MICRO BIOCIDE Cooling Water 
RXSOL-50-5002-025 Alkalinity Control 
RXSOL-40-2000-025 RXSOL 2000 corrosion inhibitor 
RXSOL-40-4009-025 MICRO BIOCIDE Cooling Water
RXSOL-50-5021-025  Hardness Control Liquid

Boiler Water Treatment Chemicals Alkalinity Control manufacturer and supplier in India UAE Oman, Alkalinity Control is most valuable Boiler water Treatment chemicals to converts calcium hardness into soft, non-adherent sludge that is easily removed by blowdown. Alkalinity controller boiler chemical manufacturer and supplier in Mumbai, Chennai, Kolkata, Visakhapatnam, Surat, Gandhidham, Chennai Ennore, Paradip, Nashisk, Pune, Varanashi, Patna, Tata, Ranchi, Fujairah, Sharjah, Ajman, Abudhabi, Dubai, UAE Gulf, Barka, Ruwi Ghala, Muscat Oman, Nairobi, Kenya, Canada

Alkalinity Builder to maintain pH of Boiler WATER. 

Boiler Alkaline Treatment Liquid

Get more with every purchase

Keep buying to get free reward points. For more details click at http://rxreward.com

 

stock-clearance.png