MICRO BIOCIDE Cooling Water
Product Description | Product Application | Product Notes| Product DOSE
Effective controller of MICRO BIOCIDE and BACTERIA from condensor WATER system. being effective against most kinds of bacteriaa, algae and fungi. It is a particularly useful product for air-wash syste
Effective controller of MICRO BIOCIDE and BACTERIA from condensor WATER system. being effective against most kinds of bacteriaa, algae and fungi. It is a particularly useful product for air-wash systems and is compatible with all commonly used antifoulants and corrosion inhibitors . For the control of microbial biofilms, bacteria, algae, and fungi, add MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 to industrial recirculating water cooling towers, industrial recirculating closed loop water cooling systems, brewery pasteurizer and can warmer systems.
Code: RXSOL-40-4009-025
Other Equivalent Brand
GREEN MICROBIOCIDE, MICROORGANISM CONTROL, Rocide BC 601, BIOCIDE INDION- 7705, Ferrocid 8583 MAXTREAT 606 CHEMICAL, Hydrex 7310, Aquatreat 2348, MAXTREAT 651, NALCO 77352, Hydrex 7908, Maxtreat 608, Nalco 2593, Indion 1591, Non Oxidising Biocide, Maxtreat 613, CareTreat 5 Seawater 25 Ltr, Aquatreat 411
Short Description:
Effective controller of MICRO BIOCIDE and BACTERIA from condensor WATER system. being effective against most kinds of bacteriaa, algae and fungi. It is a particularly useful product for air-wash systems and is compatible with all commonly used antifoulants and corrosion inhibitors.
Generic Name: MICROORGANISM CONTROLER
MICRO BIOCIDE Cooling Water
Application:
Microbiocide based on Organo sulphur compound, for use in open recircurculating systems. * Highly effective * Broad spectrum activity * Economical and easy to use * Compatible with other treatments.
Using Procedure:
Routine dosage of MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 IS 50 to 100ppm. based on the total water capacity of the system. Dosage will be necessary once or twice per week depending on the severity of
Routine dosage of MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 IS 50 to 100ppm. based on the total water capacity of the system. Dosage will be necessary once or twice per week depending on the severity of the problem.
For badly fouled systems, initial higher dosage of 100-150 ppm. should be given for the first week or two.
The calculate quantity of biocide should be added directly to the system at any convienient point.
Note:
For the control of microbial biofilms, bacteria, algae, and fungi, add MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 in recirculating water cooling towers, industrial recirculating closed loop water cooling
For the control of microbial biofilms, bacteria, algae, and fungi, add MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 in recirculating water cooling towers, industrial recirculating closed loop water cooling systems, brewery pasteurizer and can warmer systems. Add MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 at some point in the system to insure uniform mixing.
Technical Specifications:
Remarks:
Where MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 can be used?
For the control of microbial biofilms, bacteria, algae, and fungi, add MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 to industrial recirculating water cooling towers, industrial recirculating closed loop water cooling systems, brewery pasteurizer and can warmer systems. Add MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 at some point in the system to ensure uniform mixing.
Dose Ratio of MICRO BIOCIDE Cooling Water RXSOL-40-4009-025
NOTE: Badly fouled systems should be cleaned before treatment.
INITIAL DOSE: if the system is initiating fouling then use 200 ml - 3 ltr of MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 for per 3000 to 5000 Ltr of water in the system.) Dose can be increased till optimum results.
WEEKLY CONTROL DOSE: When microbial control is evident, add 100 to 500 ml per MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 for per 3000 to 5000 Ltr of water in the system
AIR WASHER SYSTEMS : Add to the air washer sump or chill water sump to insure uniform mixing, 200 ml - 3 Ltr of MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 for per 3000 to 5000 Ltr of water in the system, DOSE ration directly proportional of contamination to control microbial biofilms, bacteria, fungi, and algae which cause fouling in industrial air washer systems.
Dose Ratio of MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 for CONTINUOUS FEED METHOD
Maintain this treatment level by adding a continuous feed of 100 ml to 1000 ml of MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 per 1000 gallon of makeup water).
NOTE : Badly fouled systems must be cleaned before initial treatment.
Dose Ratio of MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 for INDUSTRIAL WASTEWATER TREATMENT SYSTEMS AND SEWAGE SYSTEMS
INITIAL DOSE for Noticeably Fouled Condition: 500 ml - 4000 ml of MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 per 3000 Ltr of water in the system. Repeat until control is achieved. Badly fouled systems should be cleaned before treatment is begun.
SUBSEQUENT DOSE: When microbial control is evident, add 100 ml - 100 ml MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 per 3000 Ltr of water in the system.
Effective controller of MICRO BIOCIDE and BACTERIA from condensor WATER system. being effective against most kinds of bacteriaa, algae and fungi. It is a particularly useful product for air-wash systems and is compatible with all commonly used antifoulants and corrosion inhibitors.
#CoolingWaterTreatmentChemicals_DubaiSharjahAjmanAbudhabi
#CoolingWaterTreatmentChemicals_MuscatOmanSohar
#CoolingWaterTreatmentChemicals_MumbaiSuratGandhidhamChennaiVizagKolkata
#MICROBIOCIDE_DubaiSharjahAjmanAbudhabi
#MICROBIOCIDE_MuscatOmanSohar
#MICROBIOCIDE_MumbaiSuratGandhidhamChennaiVizagKolkata
MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 is recommended for the control of microbial biofilms, bacteria, fungi, and algae in industrial wastewater treatment and sewage systems. Do not discharge effluent containing this product to sewer systems without previously notifying the local sewage treatment plant authority.
Equivalaent Product Name GREEN MICROBIOCIDE, MICROORGANISM CONTROL, Rocide BC 601, BIOCIDE INDION- 7705, Ferrocid 8583 MAXTREAT 606 CHEMICAL, Hydrex 7310, Aquatreat 2348, MAXTREAT 651, NALCO 77352, Hydrex 7908, Maxtreat 608, Nalco 2593, Indion 1591, Non Oxidising Biocide, Maxtreat 613, CareTreat 5 Seawater 25 Ltr
MICRO BIOCIDE Cooling Water manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai Abudhabi, Sharjah UAE, Muscat Oman, Kenya Africa. Get the best quality of MICRO BIOCIDE Cooling Water at a competitive price from us. We have ready stock of MICRO BIOCIDE Cooling Water in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.
Packing Size: 25.00 Ltr.
Available Packing Size:
MICRO BIOCIDE Cooling Water used For the control of microbial biofilms, bacteria, algae, and fungi, add MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 to industrial recirculating water cooling towers, industrial recirculating closed loop water cooling systems, brewery pasteurizer and can warmer systems. available in 5 Ltr, 25, 50, 210 Ltr PACK.
Article News:
,
HASHTAG:
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride