Skip to main content
Email :rxmarinechemical@gmail.com
Contact: 91 08069976670,
91 08069976671 , 91 08069976672

Cooling Treat 2910

Cooling Treat 2910

Cooling Treat 2910

Product Description | Product Application | Product NotesProduct DOSE

RXSOL Cool water Treat Inhibitor  is a organic liquid corrosion inhibitor with low-toxic poerty provides long-life corrosion protection for closed cooling water systems . RXSOL Cool water Treat Inhibi

Description:

RXSOL Cool water Treat Inhibitor  is a organic liquid corrosion inhibitor with low-toxic poerty provides long-life corrosion protection for closed cooling water systems . RXSOL Cool water Treat Inhibitor  will protect all commonly used materials in engine cooling water systems, including aluminium. Cool water Treat Corrosion Inhibitor  does not contain components subject to rapid depletion. Cool water Treat Inhibitor Corrosion Inhibitor for Chiller closed systems  is stable and  biodegradable.

Code: RXSOL-40-4090-025

Other Equivalent Brand Maxtreat 2910

Short Description: New Generation product fo use as Corrosion Inhibitor for Chiller closed systems

Generic Name: Corrosion Controller for Cooling System

Cooling Treat 2910

Application:

Liquid product, easy to use. Environmentally friendly, fully organic product, low toxicity. Effective against cavitation and erosion. Superior heat transfer properties. Compatible with hoses, gaskets 

Liquid product, easy to use. Environmentally friendly, fully organic product, low toxicity. Effective against cavitation and erosion. Superior heat transfer properties. Compatible with hoses, gaskets and seals. Compatible with glycols for frost protection. Stable product - non depleting. The product can be used for corrosion inhibition in many types of closed re-circulation system such as: - Diesel engine cooling water systems - Compressor cooling water systems - Centralised cooling systems - Hot water heating systems - Auxiliary machinery cooling systems.

Using Procedure:

Using Method : - RXSOL Cool water Treat Inhibitor is a highly effective corrosion inhibitor for all common metals in cooling water systems.Where most traditional inhibitors react with the metal surface and

 

Using Procedure:

Using Method : -

RXSOL Cool water Treat Inhibitor is a highly effective corrosion inhibitor for all common metals in cooling water systems.Where most traditional inhibitors react with the metal surface and form oxides that prevent further corrosion, Cool water Treat Corrosion Inhibitor  applies a thin and durable layer of protective molecules to the metal surfaces. This technology prevents the continuous build-up of insulating layers on heat transfer surfaces.

For new builds, RXSOL  recommends cleaning of the water system before commercing service. The system will always contain small amounts of oil and iron oxides, and this can be easly removed in 1 time with RXSOL Commissioning Cleaner. If the system is corroded or is more heavily contaminated use RXSOL Degreaser HD. Rxsol Safe Acid  for removal of metal oxides or scale is recommended.
For systems previously treated with other products, Our R&D team recommend to drain and flush the system before refilling with distilled water and Cool water Treat Corrosion Inhibitor . The system should be clean and free from scale and corrosion products when starting the treatment.
The use of antifreeze is sometimes required if the vessel is to be laid up in cold areas, Cool water Treat Corrosion Inhibitor  can be used in conjunction with glycols for frost protection. If used in conjunction with glycols, It is recommended to increase the product concentration to 8%.

Dosing method
Cool water Treat Corrosion Inhibitor  should be dosed to a suitable point in the system. If the expansion tank is used, adequate circulation must be assured.
Dosage and control
Cool water Treat Inhibitor  should always be present in a concentration of 5% or higher in the system. It is good practice to start with initial dose for an untreated system of 60 litres of Cool water Treat Inhibitor  / ton. 5% will provide sufficient protection of the system for a period of two to five years under normal conditions provided. To prevent residual falling below minimum level due to loss of cooling water, To get optimum result recommend to maintain a level of 6% Cool water Treat Inhibitor  in the cooling system.
The engine manufacturer's recommendations for water quality should always be complied with. Cool water Treat Corrosion Inhibitor  provides good protection even with contamination of the system by i.e. inorganc salts. Maintain Chloride levels and other contaminants at a minimum level. Most engine manufacturers recommend a maximum of 50 ppm Chlorides.

Note:

Technical Specifications:

Physical Properties
  
Density                    1.06
Packing, Type         25 Ltrs
Colour                    Colourless
Appearance            Liquid

Remarks:

 

#CoolingWaterTreat_CorrosionInhibitor
#CorrosionInhibitor_DubaiAbudhabi

Cool water Treat Inhibitor exporter, manufacturer and supplier in Mumbai, Navi Mumbai, Surat Hazira, Gandhidham Kandla, Chennai - Ennore, Vizag Visakhapatnam Gangavaram, Kolkata Haldia Paradip, Fujairah, Dubai, Surat, Abudhabi, Sharjah Middle East, Muscat Oman, Canada

Packing Size: 25.00 Ltr.

Available Packing Size: 25 Kgs

Article News:

,

HASHTAG:

#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant

#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable

#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater

#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride

TAGS

Copyright © 2021 Powered By RXMARINE - All Rights Reserved