RXSOL-50-5005-025 condensate is tested for PH to determine the dosage level. The PH limits are 8.3 - 9.0 . For an average system e. g. 10-M3, the dosage is approximately 0.65 ltr / day .
The necessary amount of Condensate Control - Condensnol amine RXSOL-50-5005-025 is required or injected as frequently as to maintain the pH of the condensate at the main condensate pump outlet between 8.6-9.5 . The amines pass over with the steam and have the dual function of elevating the pH of the steam/condensate and putting a protective micro film on the system pipe work. Acidic condensate is the result of carbonic acid (H2CO3) being formed as CO2 is released in the steam.Condensate prevents corrosion by carbonic acid on live systems. Its filming properties also reduce corrosion on shut down lines, when moisture and oxygen are present.
Condensate control cuts down such formation and facilitates in maintaining favourable environment for metalic parts. The dosage of condensate control depends on the aggregate carbonic acid content and should be added till the point the pH range is 8.3 to 9.
Email ::: mail@rxmarine.com
Available packing of Condensate control : 25 Ltr
Stock Point : Navi Mumbai - MIDC - Turbha, Gandhidham, Chennai - Ennore, Visakhapatnam - Gangavaram, Kolkata - Haldia - Paradip, Fujairah - Dubai - Abu dhabi, Sharjah.