Silica Test Kit

Silica Test Kit
SKU
RXSOL-62-5537-001
Supply Location::
Locations

Silica Test Kit manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of Silica Test Kit at a competitive price from us. We have ready stock of Silica Test Kit in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.


MUSCAT CHEMICAL TAG::
Variations
 
QUANTITY CONTENTS CODE
30 mL *Silica Test kit #1 *4571-G
15 mL *Silica Test kit #2 *4467-E
15 mL *Silica Test kit #3 *4468-E
5 mL *Reducing Reagent *6405-C
2 Test Tubes, 5 mL, glass, w/caps 0106
1 Pipet, plain, plastic 0352
1 Pipet, 0.5 mL, plastic 0353
1 Silica Octa-Slide 2 Bar,0.5-10.0 ppm 4465-01
1 Octa-Slide 2 Viewer 1101

*WARNING: Reagents marked with an * are considered to be potential health hazards. To view or print a Material Safety Data Sheet (MSDS) for these reagents go to www.rxmarine.com 
To order individual reagents or test kit components, use the specifi ed code number.

USE OF THE OCTA-SLIDE 2 VIEWER
The Octa-Slide 2 Viewer should be held so non-direct light enters through the back of the Viewer. Insert the reacted sample into the top of the Viewer. Slide the Octa-Slide 2 Bar into the Viewer and match the color of the reaction to the color standards. 

PROCEDURE
1. Fill test tube (0106) to 5 mL line with sample water.
2. Add 7 drops of *
Silica Test kit #1 (4571). Cap and mix by inverting 4 times.
3. Add 6 drops of *Silica Test kit #2  (4467). Cap and mix. Wait 5 minutes.
4. Add 6 drops of *Silica Test kit #3
 (4468). Cap and mix. Wait 2 minutes.
5. Use pipet (0352) to add 2 drops of *Reducing Reagent (6405). Cap and mix. A BLUE color will develop in 10 seconds if  
    silica is present.
6. Insert the Silica Octa-Slide 2 Bar (4465-01) into the Octa-Slide 2 Viewer (1101).
7. Insert test tube into the Octa-Slide 2 Viewer. Match sample color to a color standard. Record as ppm Silica.

NOTE: If test color is darker than the 10.0 ppm standard, repeat test on diluted sample. Use pipet (0353) to add 0.5 mL of water sample to test tube. Dilute to 5 mL line with deionized water. Follow Steps 2 through 6 above. Multiply result by 10. Record as ppm Silica 