Skip to main content
Email :rxmarinechemical@gmail.com
Contact: 91 08069976670,
91 08069976671 , 91 08069976672

Pneumatic Submersible Pump

Pneumatic Submersible Pump
SKU
RXSOL-21-2148-008
Supply Location::
Locations

Pneumatic Submersible Pump manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai, Sharjah, UAE, Gulf, Middle East, Muscat Oman, Kenya Africa. Get the best quality of Pneumatic Submersible Pump at a competitive price from us. We have ready stock of Pneumatic Submersible Pump in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.


MUSCAT CHEMICAL TAG::

Suitable to empty ballast tanks,bilge wells,etc.in emergency cases often used for draining cargo and after the washing procedure.especially preferred where an electric spark may risk ignition or explosion .air pressure is 0.59MPa(6kgf/cm2)

Note

Intended use:

STROKE Pneumatic submersible pumps are intended or use de-watering,transfer of fluids such as clear and sea water. Marine emptying of ballast tanks,damming cargo holds and pumping and sea water from bilges and holds.

It is a single stage centrifugal and driven by a powerful vane motor. Also double seals protect the bearing and motor from water and mud, and integral oilers provide continuous lubrication. Follow the instructions mentioned here to enhance the life and performance of the pump.

 

Operating instructions

Sump pump is rugged dependable equipment designed to give you years of satisfactory service. Follow the instructions mentioned here to enhance life and performance of your pump.

 

DAILY BEFORE OPERATING:

Disconnect and pour in 1to 2 ounces of recommended oil into the pump and reconnect the hose after blowing out any accumulated dirt in the hose line before connection.

 

LUBRICATION REQUIREMENTS:

Always install  a line lubricator on the air line as close to the pump as possible.A filter regulator lubricator unit (FRL)is strongly recommended. Keep the lubricator bowl topped up with the recommended grade of oil and check that the oil is reaching the pump. Running the pump without lubrication is likely to cause damage to the components causing premature replacement.

 

AIR SUPPLY:

The pump works best at 6.2 bar (90 psi) air pressure. The air should be clean, dry, lubricated.install a FRL Unit as close as operation will permit.

 

HOSES:

Daily before operation check the hoses,especially  the high pressure hoses for damage or leaks.

Use genuine teryair spares and if possible mention the serial number of the pump when ordering spares.

STORAGE:

When storing a sump pump for any length of time precautions should be taken to prevent corrosion and to maintain the pump in a serviceable condition.

  • Remove discharge and exhaust hose or pipe and run a pump out of water to blow out all moisture.

  • Remove the air line and pour a small amount of rust resistant oil in the live air inlet, re-connect hose and idle motor for a few minutes to carry oil to all internal parts.

  • Remove air hose and plug air inlet and air exhaust post with corks.

  • Wipe out the pump with rust resisting oil. Wrap pump in oiled paper and pack in covered box.

  • Store pump in dry place.

  •  

 

IMPA CODE

CAPACITY 

MAX. ALR CONSUMPTION

WATER HOUSE SIZE

AIR HOUSE SIZE

 

LIFT

DISCHARGE

591635

15

22m3/H

2.0m3/min

50mm

3/4

591636

20

28m3/H

3.4m3/min

50mm

3/4

591637

25

38m3/H

4.4m3/min

50mm

1

 


Sr.no 

Description 

Causes

1

Pump stopped and will not start

Insufficient air pressure

Check air pressure is as recommended at the pump air inlet.

Air filtered blocked

Check if debris has clogged the inlet filter on the FRL unit/pump inlet air valve(some models have air filter on the air inlet valve) and ensure clear passage of air

Internal damage or excessive wear on components

Proceed to dismantle the pump, examine components for wear,replace any worn components, reassemble carefully as instructed in this manual and re-start the pump.

2

Pump runs slowly, poor delivery.

Insufficient or wrong lubricant in the air supply.

Ensure that the lubricant is as per the recommended chart, a thicker lubricant aften makes the air valve work sluggishly.


Internal damage or excessive wear on components

Proceed to dismantle the pump,examine components for wear, replace any worn components,ressemble carefully as instructed in this manual and re-start the pump.

3

Motor is jammed

Worn or damaged rotor blades

Dis-assemble governor housing (7)and motor housing (35) clean all parts in a light solvent.replace worn or damaged parts and reassemble.

 
 

Copyright © 2021 Powered By RXMARINE - All Rights Reserved