To clean an air cooler, you can use a RXSOL ACC9 mixture with water . You can also use direct RXSOL ACC9 air cooler cleaning agents, which are specially formulated to clean and sanitize the cooler. which is safe and suitable for the air cooler, as some cleaners may cause damage to certain types of surfaces.
Air Cooler Cleaner Manufacturer supplier in Kolkata Howrah, Mumbai MIDC, Surat Hazira, Kandla Gandhidham Gujrat, Chennai Ennore, Vizag Visakhapatnam, Paradip, Buzbuz and in UAE RXSOL Air cooler cleaner manufacturer and supplier in Dubai, Sharjah, Ajman, Abudhabi, Fujairah Gulf, Muscat Barka, Ruwi Barka, Oman, Nairobi Kenya, Sudan Yemen
MUSCAT CHEMICAL TAG::
Air Cooler Chemical cleaner - ACC-XXX9 plays very important role during cleaning and maintenance of Air cooler tube, fins and all accessories of Air cooler. Air Cooler Chemical cleaner - ACC-XXX9 also can be use to clean carbon depsosit from all engine component and we added additional value of surfactant in to Air Cooler Chemical cleaner - ACC-XXX9 to result heavy degreasing action in engine maintenance area. Our continious work since 1995 enable us to product premium quality Air Cooler Chemical cleaner - ACC-XXX9 to acts as superior air cooler cleaner as well as resulting as good carbon remover and degreaser.
Air Cooler Chemical cleaner - ACC-XXX9 packed in 25 Ltrs packing for export purpose. And our regular customers and export agent also using there own brand under our Private labeling option. In our private labeling option reserved all privacy rights under our standard terms and condition.. Air Cooler Chemical cleaner - ACC-XXX9 is most popular and specialized product for SHIPPING and marine industries.
We are also making direct supply of Air Cooler Chemical cleaner - ACC-XXX9 on ship through our authorized shipchandler of various location. We are keeping ready stock of Air Cooler Chemical cleaner - ACC-XXX9 at our ware house of Mumbai, Kandla - Gandhidham, Surat, Kolkata - Haldia, Vizag - Gangavaram, Chennai - Ennore, Fujairah, Dubai.
1. It is a powerful solvent emulsion cleaner for cleaning of diesel engine air coolers, scavenging air systems and compressor ...
2. Air Cooler Chemical cleaner - ACC-XXX9 is a liquid compound consisting of specific corrosion inhibitors , to prtect SOFT METAL
Field :: - AHU, FCU, Air Conditioners, Car Condenser and Radiator, Air Cooled Chillers, Air Cooled Condensers, Air Cooler Tube Bundle etc.
It has self foaming characteristics which starts immediate foaming when it comes in contact with dirt, enabling excellent penetration of the product into the coils for complete cleaning that instantly shows multiple increase of CFM/Air Velocity.
During the operation, the fins & tubes of the main engine air cooler which become fouled with oil, grease, dust and carbonaceous deposit , which will affect cooler efficiency and damage the system. Air Cooler Chemical cleaner - ACC-XXX9 MSDS and Technical bulletines are available online as well as you can drop your mail to get in pdf format.
Hand spray Cleaning: By Hand spray,apply concentrate RXSOL-16-0009-210 all over the cooler coils. for good emulsification &penetration. Allow the RXSOL-16-0009-210 for a minimum of 10 MINUTES then use a high pressu ure water to wash off the loosened deposits. During process always keep drain valve open. After satisfactory cleaning, and flushing through with fresh water, close air cooler drains.Note that during this process the engine must be stopped.
Immersion bath
Atleast for 2 Hrs deep COOLER PARTS in to Air Cooler Chemical cleaner - ACC-XXX9 emulsion tank. The product should be heated to approx. 50°C and agitation provided with an air line. Then drain off and flush well with water, followed by drying with an air line.
Soak method: Machine parts with stubborn carbon deposits to be cleaned is dipped into conc.Soln.of ACC then allow deposits to. Be broken down and loosened before removal, then rinse .
Circulation method
Some designs of cooler can be circulated "in situ". In this case a pump tank and pipe system is fitted permanently or connections are provided for connecting a temporary circuit. The system should be filled with Air Cooler Chemical cleaner - ACC-XXX9 circulation carried out for 2 - 4 hours at a temperature of upto 50°C. After cleaning the cooler should be thoroughly flushed with fresh water and dried with an air line.
Note: Both cleaning methods benefit from heat of up to 50°C and cleaning times can be reduced or extended dependant on temperature and degree of fouling.
For effective cleaning of air coolers, scavenging air systems and turbo chargers of diesel engines.
3 to 5 litres of cleaning solution per square meter or as table below:
Engine HP. Solution of RXSOL 009
6,000 to 12,000 2 to 3 litre
12,000 to 24,000 4 to 5 litre
24,000 or more 5 to 6 litre
In General : Depending upon contamination 10-25% with fresh water.
OPTIONAL : Dependant on design, the cooler is flooded with Air Cooler Chemical cleaner - ACC-XXX9 immersed in a tank full of product.