Skip to main content
Email :rxmarinechemical@gmail.com
Contact: 91 08069976670,
91 08069976671 , 91 08069976672

BRINE CORROSION INHIBITOR

Brine Corrosion Inhibitor RXSOL  is a Fatty amine derivative with biocide and oxygen scavenger borate-organic corrosion inhibitor especially designed for use in chloride brine closed re-circulating cooling systems. Brine Corrosion Inhibitor RXSOL  provides effective corrosion protection for steel and most other metals in both low and high temperature systems and is formulated to perform without additional supplements. It can be used in chromate containing systems without causing precipitation.

Remarks
Miscibility Dose 10% v/v can be use in NaCl and CaCl2 Brine reicrulating solution
 
1% by Volume in Brine Having Specific Gravity of 1.15
 
Efficiency : 90% minimum corrosion protection
Note

Features

  • Formulated for brine cooling systems
  • Liquid - easy to handle.
  • Multi metal corrosion protection.

Benefits

  • Can be used to replace chromate technology

Physical Properties :

- Odour: Odourless
- Appearance: colourless to yellow, miscible with water
- pH 11,5 - 14
- Boiling point 100 °C at 760 mm /Hg
- Density 1,155 - 1,190 g/cm3 at 20 deg C

Corrosion Inhibitor chloride brine closed re-circulating cooling systems.

The recommended dosage for Brine Corrosion Inhibitor RX is 17.5 litres per tonne of brine in the system. Brine Corrosion Inhibitor Rx may be added directly to the system either neat or in a water dilution. Dilutions should be made with evaporated water. If a chemical dosing pump is used then pump and lines should be mild steel, stainless steel, Teflon, polyethylene, PVC, polypropylene or rubber.

Conversion from chromate Brine corrosion inhibitor RX is compatible with chromate. Systems with chromate need not be flushed before adding the product. Let chromate deplete naturally and maintain boron level at a minimum of 70ppm. Brine Corrosion Inhibitor Rx should be fed slowly. Start feeding 5 to 10% of the total dosage at a time and watch for foaming. Gradually increase the feed rate. Brine Corrosion Inhibitor Rx does not induce foaming at normal dose rates, but if it is fed too much too soon, foaming may occur. Feed lines and pumps should be mild steel, stainless steel, Teflon, polyethylene, PVC polypropylene or rubber.

Testing and Control Control Brine Corrosion Inhibitor RXSOL as Boron at 70 - 100 ppm Note: Because the specific gravity of the brine varies with concentration, the resulting level of boron should be calculated.

Copyright © 2021 Powered By RXMARINE - All Rights Reserved