Degreaser Heavy Duty Alkaline Cleaner manufacturer, supplier and exporter in India, Oman, UAE. We are keeping ready stock of Degreaser Heavy Duty Alkaline Cleaner at Mumbai, Visakhapatnam, Chennai, Kolkata, Gandihdham, Sharjah Dubai Abudhabi, Muscat Sohar Oman
MUSCAT CHEMICAL TAG::
For removal of tough soils and its wide range of dilutions accommodate most any cleaning application. Universal, concentrated product for cleaning and degreasing surfaces using various manual and mechanized methods. It can even be used in pressure washer applications or hand steaming. Heavy duty alkaline cleaner can be used as All-purpose cleaner and degreaser uses a blend of detergents and a water-soluble solvent to remove tough soils. Compatible with a broad range of dilutions to accommodate any cleaning application.
Also useful for BOILER and General INDUSTRIAL cleaning PURPOSE.
Storage: Store in the original packaging or in specially appropriate containers, protected from heat sources.
Powerful cleaner its uses is Versatile and economical and It softens hard water Without odor and noxious fumes Easy to wash off Biodegradable, non-toxic, contains no VOCs base modifications, (minor modifications of content in Unikleen HD) does not contain ammonia or acid and not corrosive to metal, non-irritating to the skin and the respiratory tract. Passivating to metal surfaces Operates at low (from 30°C or 86 °F ) temperatures of the working solution It does not create a stable emulsion with washed out contaminants It has a long service life in the working solution.
Safety: Avoid contact with eyes. Avoid prolonged or repeated contact with skin. Wash contaminated clothing before reusing. Wash thoroughly after handling.
Form / Phase : Homogenious liquid
Specific Gravity: 1.052 at 20 °C (68°F) , g / cm3
Flash Point: NA
Freeze Point: 32°F
pH: 13–14 For Heavy Duty Grade and In general 9 - 10
Odor: slight/butyl
This product is recommended as a wall and floor cleaner in industrial facilities. May be used in pressure washer applications or hand steaming. Powerful cleaner/degreaser with controlled foam. Variable dilutions for the wide variety of applications. Economical choice. Effective cleaner.
This is an aqueous surfactant solution, alkaline base, food-grade phosphate product. Effective for degreasing and removal of oil residue, animal fat and vegetable bases on different surfaces: industrial equipment, including food, assemblies, transport, tanks, walls, floors and other surfaces, manual and machine washing of textiles and clothing. It has an average foaming capability when applied by hand or with the help of floor cleaning machines, pressure washers, equipment for foam cleaning.
-
Food service establishments
-
Hotels and motels
-
Educational facilities
-
Any general cleaning task
-
Heavy Industries and in PLANT area
This product is recommended as a wall and floor cleaner in industrial facilities, food service establishments hotels and motels educational facilities any general cleaning task.
It is also used in mechanical engineering, petroleum, and food industries, railway transport, office and warehousing, utilities and other industries.
Dilute concentrated cleaner with warm water using 1 part Heavy Duty Alkaline Cleaner and 1 part water.
Apply mixed solution with a mop, sponge or sprayer. Avoid applying cleaner on unintended surfaces.
Lightly rub with a scrub brush or floor machine as needed. Allow cleaner for emulsification 1 to15 minutes for best results— do not allow to dry on the surface.
Remove solution using a sponge, wet/dry vacuum or damp mop.
Rinse the area well with clean water.
TYPICAL METHOD::: Dilute to proper ratio for the desired task, apply to surface and allow adequate contact time, wipe or rinse away.
Can be Use dilution of 1:100: 11.0 - 11.5 (1:100).
GENERALLY ::: In an aqueous solution, at a concentration from 10 ml to 200 ml per liter of water, depending on the degree of contamination.
For Boiler Cleaning :::
5 Ltr is sufficient for 1000 LTRS OF WATER.
The boiler should be warmed through by a slow fire, keeping the manhole closed, immediately after adding the chemical and pressure allowed to rise slowly. It should be raised sufficiently to
give a strong blow of steam at the air cocks. It should be allowed to cool and later blown down for about 15 seconds on each blow-down valve and refilled to about 5 cm level in the gauge glass. On the following day, carry out the same process except that the pressure is raised to approx 25 percent of the normal working pressure. On the third day, carry out the same process and then drain the boiler as detailed below –
When the pressure falls to 0.04 MN/m2 (0.4 kgf/cm2), the unit is blown down completely until it is empty, refilled to flood the drum and superheater and blown down again. It should then be carefully inspected. If any trace of oil or grease is observed, the process of boiling-out should be repeated. If the boiler is found free from grease or oil or sediment, it should be closed and filled with feed water as specified by the manufacturer.
Degreaser Heavy Duty Alkaline Cleaner manufacturer, Supplier and exporter.