Product Notes

INSTALLATION AND EQUIPMENT:

Tanks:  Mild or stainless steel or other materials suitable for use with alkaline solutions.

Heaters: PTFE, stainless steel or mild steel immersion heaters or steam coils. It is essential that the tanks to be used for Soak Clean Eco HD are thoroughly cleaned and leached before any product is introduced. If in any doubt as to the cleaning procedure please contact PMD Technical Department.

1. ¾ fill tank with water.

2. Add the required weight of Soak Clean Eco HD with stirring to dissolve.

3. Make up to final volume with water.

4. Heat to operating temperature.

MAINTENANCE AND CONTROL

The volume of the solution should be maintained regularly by the addition of water. It is recommended that automatic level controllers are fitted to the tank to ensure constant solution concentration and protect heaters.

The solution should be analysed regularly and replenished as necessary. (See analysis method).

The solution should be discarded and a fresh one made-up when the solution is so loaded with absorbed soils that replenishment has no effect on cleaning time.

SOLUTION MAKE -UP

Econoclense NS                           25 - 100 g/L depending on soils.

Using Procedure and operting data :

Concentration 25 – 100g/L
Temperature                                      50 – 90°C
Time As required
Agitation Mild agitation is useful to ensure thorough cleaning.