Cleaning Procedure
Tank Cleaning Sludge/ Lube Oils / Slope-Black Oil:-
1 ) Fill the tank with 1-35 litres per ton wash water.Best results are obtained when water is heated to a temperature between 65°C & 80°C then stripped constantly and transferred to a holding tank for separation.The time for this will vary depending on amount of RXSOL-20-2059-210 used & nature of oil being cleaned.Generally,12 hours should be sufficient before the water phase can be removed.
2) Direct Cleaning.Spray directly RXSOL-20-2059-210 on tank surfaces to be cleaned, left for at least 30 minutes.Finally wash with hydrogating (high pressure) machine. Hot water between 50°C & 80°C recommended.
Related Products : ORG 5 ,ORG 14,ORG 15,ORG 16